Suppr超能文献

犬类微环境中屋尘螨及屋尘螨过敏原的定量分析

Quantitation of house dust mites and house dust mite allergens in the microenvironment of dogs.

作者信息

Randall Amy, Hillier Andrew, Cole Lynette K, Kwochka Kenneth W, Needham Glen, Wassom Donald L

机构信息

Department of Veterinary Clinical Sciences, College of Veterinary Medicine The Ohio State University, Columbus, OH 43210, USA.

出版信息

Am J Vet Res. 2003 Oct;64(10):1301-9. doi: 10.2460/ajvr.2003.64.1301.

Abstract

OBJECTIVE

To quantitate the density of Dermatophagoides farinae and D pteronyssinus and concentrations of house dust mite (HDM) allergens (Der f 1, Der p 1, and Group 2 allergens) in the indoor microenvironment of dogs. Sample Population-50 homes in Columbus, Ohio.

PROCEDURES

n each home, samples of dust were collected from 3 locations in which dogs spent most time. Whenever possible, the species of mites collected was identified. Mite density (mites/g of dust) was assessed, and allergen concentrations were assayed by standardized ELISAs. Relative humidity and temperature in each home were monitored during a 5-day period. Characteristics of homes and sample sources were evaluated.

RESULTS

Dust samples from all 50 homes contained > or = 1 HDM allergen; Der f 1 and Der p 1 were detected in 100 and 74% of homes, respectively. Fifteen homes had HDMs; compared with D pteronyssinus, D farinae was found more commonly (14/15 homes) and at a higher density. Basements, homes without central air-conditioning, and dog beds that were > or = 1 year old had high HDM allergen concentrations. Homes with > or = 2 microg of Der f 1 or Group 2 allergens/g of dust or > or = 100 mites/g of dust were significantly more likely to have a maximum relative humidity > or = 75%.

CONCLUSIONS AND CLINICAL RELEVANCE

Results indicate the presence of HDMs and HDM allergens in the specific microenvironment of dogs in homes. Factors associated with high levels of exposure were identified, which may be associated with increased risk for sensitization and development of atopic diseases.

摘要

目的

对犬类室内微环境中的粉尘螨和屋尘螨密度以及屋尘螨(HDM)过敏原(Der f 1、Der p 1和2类过敏原)浓度进行定量分析。样本群体——俄亥俄州哥伦布市的50户家庭。

程序

在每户家庭中,从犬类最常活动的3个地点采集灰尘样本。尽可能鉴定所采集螨虫的种类。评估螨虫密度(每克灰尘中的螨虫数量),并通过标准化酶联免疫吸附测定法检测过敏原浓度。在5天时间内监测每户家庭的相对湿度和温度。评估家庭和样本来源的特征。

结果

所有50户家庭的灰尘样本均含有≥1种HDM过敏原;分别在100%和74%的家庭中检测到Der f 1和Der p 1。15户家庭中有HDM;与屋尘螨相比,粉尘螨更常见(14/15户家庭)且密度更高。地下室、没有中央空调的家庭以及使用年限≥1年的狗窝中HDM过敏原浓度较高。每克灰尘中Der f 1或2类过敏原含量≥2微克或每克灰尘中螨虫数量≥100只的家庭,其最大相对湿度≥75%的可能性显著更高。

结论及临床意义

结果表明在家庭中犬类的特定微环境中存在HDM和HDM过敏原。确定了与高暴露水平相关的因素,这可能与致敏风险增加和特应性疾病的发生有关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验