使用Dinamap PRO 100自动示波装置测量血压时的变异性来源。

Sources of variability in blood pressure measurement using the Dinamap PRO 100 automated oscillometric device.

作者信息

Chang Joseph J, Rabinowitz Daniel, Shea Steven

机构信息

Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.

出版信息

Am J Epidemiol. 2003 Dec 15;158(12):1218-26. doi: 10.1093/aje/kwg274.

Abstract

The Dinamap automated oscillometric device (GE Medical Systems Information Technologies, Inc., Milwaukee, Wisconsin) for blood pressure measurement is widely employed in epidemiologic studies because it is easy to use and because it eliminates observer variability. In this study, the authors assessed the variability in observed blood pressures associated with use of the Dinamap monitor and estimated the contributions of various factors to that variability. In 60 volunteers (30 aged 23-35 years and 30 aged 54-82 years) from New York, New York, the authors obtained 30 simultaneous paired blood pressure measurements in both arms at 1-minute intervals, using three separate Dinamap PRO 100 devices allocated to arm and subject according to a balanced incomplete block design. Variability, defined as the between-arm difference in blood pressure measurements, was analyzed using a mixed-effects linear regression model. A total of 1,800 paired blood pressure measurements were obtained between September 2001 and June 2002. The mean ages of the two groups were 28.3 years (standard deviation, 4.0) and 71.7 years (standard deviation, 8.0). A diagnosis of hypertension was present in 53% of the older subjects and none of the younger subjects. Fifty percent of paired simultaneous blood pressure measurements obtained were in agreement within 4 mmHg for systolic blood pressure or within 3 mmHg for diastolic blood pressure. Residual variability, attributable to the intrinsic inaccuracy of the device, accounted for 64-82% of the total systolic and diastolic blood pressure variability. The majority of variability in blood pressure measurement was due to the device as used under the study conditions.

摘要

用于血压测量的Dinamap自动示波装置(通用电气医疗系统信息技术公司,威斯康星州密尔沃基)在流行病学研究中被广泛使用,因为它易于操作且消除了观察者差异。在本研究中,作者评估了使用Dinamap监测仪时观察到的血压变异性,并估计了各种因素对该变异性的影响。在来自纽约市的60名志愿者(30名年龄在23 - 35岁之间,30名年龄在54 - 82岁之间)中,作者按照平衡不完全区组设计,将三台独立的Dinamap PRO 100设备分配到手臂和受试者,以1分钟的间隔同时在双臂获取30对血压测量值。变异性定义为血压测量值的双臂差异,使用混合效应线性回归模型进行分析。在2001年9月至2002年6月期间共获得了1800对血压测量值。两组的平均年龄分别为28.3岁(标准差4.0)和71.7岁(标准差8.0)。老年受试者中有53%被诊断为高血压,而年轻受试者中无人患高血压。所获得的成对同步血压测量值中,50%的收缩压在4 mmHg以内或舒张压在3 mmHg以内一致。归因于设备固有不准确性的残余变异性占收缩压和舒张压总变异性的64% - 82%。在研究条件下使用时,血压测量的大部分变异性是由设备引起的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验