Over 2000 measurements have been made on a mammaphantom to ascertain radiation exposure curves for skin and parenchyma. The exposure of the parenchyma is definitely depending on the thickness of the fatlayer above the parenchyma. Until now radiation exposure was calculated under the assumption that the different breast tissues are equally distributed. In doing so exposure was estimated too high (up to a factor 3-especially in fatter breasts). The individual absorbed dose in the parenchyma can be reckoned out by the various figures and tables, which consider technical criteria, different sizes of the breast and two film systems.

摘要

已经对一个乳房模型进行了2000多次测量,以确定皮肤和实质的辐射暴露曲线。实质的暴露肯定取决于实质上方脂肪层的厚度。到目前为止,辐射暴露是在不同乳腺组织均匀分布的假设下计算的。这样做时,暴露估计过高(高达3倍——尤其是在较胖的乳房中)。可以通过考虑技术标准、乳房不同尺寸和两种胶片系统的各种图表来计算实质中的个体吸收剂量。