[Radiation exposure of the operator during angiography (author's transl)].

作者信息

Lackner K, Ewen K, Felix R

出版信息

Rofo. 1978 Jan;128(1):86-90. doi: 10.1055/s-0029-1230796.

Abstract

Radiation exposure to the forehead, hand, sternum and gonads of the operator was measured with a LiF dose meter during 134 angiocardiograms and 56 angiograms of the abdomen and the extremities. Average exposure during angiocardiography to the forehead was 3.2 mrem., to the hand 4.2 mrem. and the gonads and sternum about 0.5 mrem. per examination. During angiography of the abdomen and extremities, exposure was rather higher. The results of these measurements are compared with the findings of other authors and relate to dose-dependant somatic damage.

摘要

在134例心血管造影及56例腹部和四肢血管造影过程中,使用氟化锂剂量仪测量了操作者前额、手部、胸骨和性腺的辐射暴露情况。心血管造影检查期间,前额的平均暴露剂量为3.2毫雷姆,手部为4.2毫雷姆,性腺和胸骨每次检查约为0.5毫雷姆。在腹部和四肢血管造影期间,暴露剂量要高得多。将这些测量结果与其他作者的研究结果进行了比较,并涉及剂量依赖性躯体损伤。