Suppr超能文献

白内障摘除术后术前10赫兹视觉诱发电位与对比敏感度和视力的比较。

Comparison of preoperative 10-Hz visual evoked potentials to contrast sensitivity and visual acuity after cataract extraction.

作者信息

Cavender S A, Hobson R R, Chao G M, Weinstein G W, Odom J V

机构信息

Department of Ophthalmology, West Virginia University Health Sciences Center, Morgantown 26506.

出版信息

Doc Ophthalmol. 1992;81(2):181-8. doi: 10.1007/BF00156007.

Abstract

Cataract patients whose surgical outcomes were in question were referred for testing by visual evoked potentials, elicited through closed eyelids by a luminance stimulus (flash) that appeared 10 times per second. Visual evoked potentials were rated as normal (predicted acuity of 20/50 or better) or abnormal (predicted acuity of 20/60 or worse). Postoperative Arden and Optronix contrast sensitivities and visual acuities were determined in 37 patients who had no intraoperative or early postoperative complications. Arden grating scores of less than 100 were rated as normal. The optimal and cutoff spatial frequency values were determined for the Optronix scores. Optimal and cutoff values of greater or equal to 1 c/deg and 12 c/deg, respectively, were rated as normal. Visual acuities were considered normal at 20/50 or better. Preoperative visual evoked potentials were quantitatively compared to the postoperative contrast sensitivities and visual acuities by 2 x 2 contingency tables. The accuracy of prediction was 79% for the visual acuities, 62% for the Optronix optimal values, 70% for the Optronix cutoff values and 62% for the Arden gratings.

摘要

手术结果存疑的白内障患者被转介进行视觉诱发电位测试,通过每秒出现10次的亮度刺激(闪光)在闭眼状态下诱发。视觉诱发电位被评定为正常(预测视力为20/50或更好)或异常(预测视力为20/60或更差)。对37例无术中或术后早期并发症的患者测定了术后阿登(Arden)和奥普特罗尼克斯(Optronix)对比敏感度及视力。阿登光栅评分低于100被评定为正常。确定了奥普特罗尼克斯评分的最佳和截止空间频率值。最佳值和截止值分别大于或等于1 c/deg和12 c/deg被评定为正常。视力在20/50或更好时被视为正常。通过2×2列联表对术前视觉诱发电位与术后对比敏感度和视力进行了定量比较。视力的预测准确率为79%,奥普特罗尼克斯最佳值为62%,奥普特罗尼克斯截止值为70%,阿登光栅为62%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验