• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Use of D-T-produced fast neutrons for in vivo body composition analysis: a reference method for nutritional assessment in the elderly.

作者信息

Kehayias J J

机构信息

USDA Human Nutrition Research Center on Aging at Tufts University, 711 Washington St., Boston, 02111-1524 MA, USA.

出版信息

Anal Bioanal Chem. 2004 May;379(2):188-91. doi: 10.1007/s00216-003-2479-8. Epub 2004 Jan 28.

DOI:10.1007/s00216-003-2479-8
PMID:14747891
Abstract

Body composition has become the main outcome of many nutritional intervention studies including osteoporosis, malnutrition, obesity, AIDS, and aging. Traditional indirect body composition methods developed with healthy young adults do not apply to the elderly or diseased. Fast neutron activation (for N and P) and neutron inelastic scattering (for C and O) are used to assess in vivo elements characteristic of specific body compartments. Non-bone phosphorus for muscle is measured by the (31)P(n, alpha)(28)Al reaction, and nitrogen for protein via the (14)N(n,2n)(13)N fast neutron reaction. Inelastic neutron scattering is used to measure total body carbon and oxygen. Body fat is derived from carbon after correcting for contributions from protein, bone, and glycogen. Carbon-to-oxygen ratio (C/O) is used to measure the distribution of fat and lean tissue in the body and to monitor small changes of lean mass. A sealed, D-T neutron generator is used for the production of fast neutrons. Carbon and oxygen mass and their ratio are measured in vivo at a radiation exposure of less than 0.06 mSv. Gamma-ray spectra are collected using large BGO detectors and analyzed for the 4.43 MeV state of carbon and 6.13 MeV state of oxygen, simultaneously with the irradiation. P and N analysis by delayed fast neutron activation is performed by transferring the patient to a shielded room equipped with an array of NaI(Tl) detectors. A combination of measurements makes possible the assessment of the "quality" of fat-free mass. The neutron generator system is used to evaluate the efficacy of new treatments, to study mechanisms of lean tissue depletion with aging, and to investigate methods for preserving function and quality of life in the elderly. It is also used as a reference method for the validation of portable instruments of nutritional assessment.

摘要

相似文献

1
Use of D-T-produced fast neutrons for in vivo body composition analysis: a reference method for nutritional assessment in the elderly.
Anal Bioanal Chem. 2004 May;379(2):188-91. doi: 10.1007/s00216-003-2479-8. Epub 2004 Jan 28.
2
In vivo elemental partition analysis using fast neutrons. A tool for testing the efficacy of new clinical interventions.使用快中子进行体内元素分配分析。一种测试新临床干预措施疗效的工具。
Ann N Y Acad Sci. 2000 May;904:140-7. doi: 10.1111/j.1749-6632.2000.tb06437.x.
3
In vivo determination of body fat by measuring total body carbon.通过测量全身碳含量对体内脂肪进行测定。
Am J Clin Nutr. 1991 Jun;53(6):1339-44. doi: 10.1093/ajcn/53.6.1339.
4
Assessment of body fat and lean in the elderly by measuring body carbon and oxygen: validation against hydrodensitometry.通过测量身体碳和氧评估老年人的体脂和瘦体重:与水下密度测量法的验证对比
Appl Radiat Isot. 1998 May-Jun;49(5-6):723-5. doi: 10.1016/s0969-8043(97)00095-x.
5
Use of fast neutrons for measuring muscle.使用快中子测量肌肉。
Appl Radiat Isot. 1998 May-Jun;49(5-6):737-8. doi: 10.1016/s0969-8043(97)00098-5.
6
Application of the associated particle technique for the whole-body measurement of protein, fat and water by 14 MeV neutron activation analysis--a feasibility study.利用14兆电子伏中子活化分析的关联粒子技术进行蛋白质、脂肪和水的全身测量——一项可行性研究。
Phys Med Biol. 1995 Jun;40(6):1045-55. doi: 10.1088/0031-9155/40/6/006.
7
A feasibility study of in vivo 14-MeV neutron activation analysis using the associated particle technique.
Med Phys. 1991 Sep-Oct;18(5):916-20. doi: 10.1118/1.596714.
8
The feasibility of measuring total body carbon by counting neutron inelastic scatter gamma rays.通过计数中子非弹性散射伽马射线来测量全身碳含量的可行性。
Phys Med Biol. 1982 Jun;27(6):805-17. doi: 10.1088/0031-9155/27/6/003.
9
A feasibility study of prompt capture gamma in vivo neutron activation analysis.即时捕获γ射线体内中子活化分析的可行性研究。
Med Phys. 1979 May-Jun;6(3):179-92. doi: 10.1118/1.594631.
10
Calibration of a prototype in vivo total body composition analyser using 14 MeV neutron activation and the associated particle technique.使用14兆电子伏中子活化和相关粒子技术对一种原型活体全身成分分析仪进行校准。
Appl Radiat Isot. 1998 May-Jun;49(5-6):537-9. doi: 10.1016/s0969-8043(97)00070-5.