The objective of this study was to identify whether muscle mechanoreceptor stimulation is capable of modulating sweat rate. Seven healthy subjects performed two 20-min bouts of supine exercise on a tandem cycle ergometer (60 rpm at 65% of maximal heart rate). After one bout, the subject stopped exercising (i.e., no pedaling), whereas, after the other bout, the subject's legs were passively cycled (at 60 rpm) via a second person cycling the tandem ergometer. This allows for mechanical stimulation of muscle with minimal activation of central command. Esophageal temperature (T(es)), mean skin temperature (T(sk)), heart rate, mean arterial blood pressure, oxygen consumption, cutaneous vascular conductance (CVC), and sweat rate were not different during the two exercise bouts. Regardless of the mode of exercise recovery, there were no differences in T(es), T(sk), or CVC. In contrast, early in the recovery period, chest and forearm sweat rate were significantly greater in the passive cycling recovery mode relative to the no-pedaling condition (chest: 0.57 +/- 0.13 vs. 0.39 +/- 0.14, forearm: 0.30 +/- 0.05 vs. 0.12 +/- 0.02 mg.cm(-2).min(-1); both P < 0.05). These results suggested that muscle mechanoreceptor stimulation to the previously activated muscle is capable of modulating sweat rate.

摘要

本研究的目的是确定肌肉机械感受器刺激是否能够调节出汗率。七名健康受试者在串联式自行车测力计上进行了两轮20分钟的仰卧运动(以最大心率的65%,60转/分钟)。一轮运动后,受试者停止运动(即不蹬踏板),而在另一轮运动后,受试者的腿部通过另一个人蹬串联测力计被被动地带动做圆周运动(60转/分钟)。这使得在最小程度激活中枢指令的情况下对肌肉进行机械刺激。在两轮运动期间,食管温度(T(es))、平均皮肤温度(T(sk))、心率、平均动脉血压、耗氧量、皮肤血管传导率(CVC)和出汗率没有差异。无论运动恢复模式如何,T(es)、T(sk)或CVC均无差异。相比之下,在恢复早期,被动循环恢复模式下胸部和前臂的出汗率显著高于不蹬踏板的情况(胸部:0.57±0.13对0.39±0.14,前臂:0.30±0.05对0.12±0.02毫克·平方厘米⁻¹·分钟⁻¹;P均<0.05)。这些结果表明,对先前激活的肌肉进行肌肉机械感受器刺激能够调节出汗率。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验