Suppr超能文献

尼德克EAS 1000系统与拓普康SL - 45在临床应用中的比较。

Comparison of the Nidek EAS 1000 system and the Topcon SL-45 in clinical application.

作者信息

Wegener A, Hockwin O, Laser H, Strack C

机构信息

Department of Experimental Ophthalmology, University of Bonn, FRG.

出版信息

Ophthalmic Res. 1992;24 Suppl 1:55-62. doi: 10.1159/000267209.

Abstract

Some years ago, Nidek developed a new imaging system for the anterior eye segment, which offers the possibility of recording Scheimpflug and retroillumination images. The system consists of 2 different technical units, a camera unit for image recording and a computer unit for storage, system operation and image analysis. To evaluate the clinical use of the system and its reproducibility, a study with 31 volunteers/patients was performed that were photographed with the Nidek EAS 1000 at the meridians 0 degree, 45 degrees and 180 degrees. Two examinations with a 1-week interval were performed. In addition, a direct comparison of the EAS 1000 with the Topcon SL-45 was carried out with 32 volunteers that were photographed at 0 degree and 45 degrees; a retroillumination photo was additionally recorded. The video images were evaluated with the computer software, the SL-45 negatives were standardly measured with a Joyce-Loebl densitometer. The handling of the EAS 1000 in clinical use was found to be easy and comfortable for the patient, as the alignment is done with infrared light. Difficulties occur only with the retroillumination photography in that the infrared light for imaging may outshine the red fixation light during exposure. However, shadowing problems due to the eyelashes occur in oblique slit positions, especially in those patients with a pronounced front head. In studying the reproducibility, the mean values of the individual coefficients of variation for light scattering (density) were in a range between 3.6 and 5.06%, but more than 35% of the single values show a variation coefficient above 5% (maximum 20.3%).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

几年前,尼德克公司开发了一种用于眼前节的新型成像系统,该系统能够记录Scheimpflug图像和后照图像。该系统由两个不同的技术单元组成,一个用于图像记录的相机单元和一个用于存储、系统操作及图像分析的计算机单元。为评估该系统的临床应用及其可重复性,对31名志愿者/患者进行了一项研究,他们在0度、45度和180度子午线处用尼德克EAS 1000进行拍照。每隔1周进行两次检查。此外,对32名志愿者在0度和45度处拍照,将EAS 1000与拓普康SL-45进行直接比较;另外还记录了一张后照照片。用计算机软件对视频图像进行评估,用乔伊斯-勒布尔密度计对SL-45底片进行标准测量。发现EAS 1000在临床使用中对患者来说操作简便且舒适,因为校准是通过红外光完成的。困难仅出现在后照摄影中,即成像用的红外光在曝光时可能会比红色固定光更亮。然而,在斜向裂隙位置会出现由于睫毛导致的阴影问题,尤其是在那些额头突出的患者中。在研究可重复性时,光散射(密度)的各个变异系数的平均值在3.6%至5.06%之间,但超过35%的单个值显示变异系数高于5%(最大值为20.3%)。(摘要截选至250词)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验