Suppr超能文献

三种压缩式助听器初次适配方法的比较。II. 有经验的单侧适配用户。

Comparison of three procedures for initial fitting of compression hearing aids. II. Experienced users, fitted unilaterally.

作者信息

Alcántara José I, Moore Brian C J, Marriage Josephine

机构信息

Department of Experimental Psychology, University of Cambridge, Cambridge, UK.

出版信息

Int J Audiol. 2004 Jan;43(1):3-14. doi: 10.1080/14992020400050003.

Abstract

This paper is the second in a series comparing three procedures for the initial fitting of multichannel compression hearing aids. The first paper reported the results for a group of 10 experienced hearing aid users fitted bilaterally. This paper reports the results for a different group of 10 experienced hearing aid users fitted unilaterally. The three procedures were: (1) CAMEQ, which aims to amplify speech so as to give equal loudness per critical band over the frequency range 500-5000 Hz, and to give similar overall loudness to normal over a wide range of speech levels; (2) CAMREST, which aims to amplify speech so as to restore normal specific loudness patterns, over a wide range of speech levels; and (3) DSL [i/o], which aims to map the dynamic range of normal-hearing people into the reduced dynamic range of hearing-impaired people, with full restoration of audibility. Each subject was fitted with one Danalogic 163D digital hearing aid, using each of the three fitting procedures in turn; the order was counter-balanced across subjects. Prescribed insertion gains for 55 and 80 dB SPL input levels were verified using real-ear measurements. Immediately after fitting with a given procedure, and 1 week after fitting. the gains were adjusted, when required, by the minimum amount necessary to achieve acceptable fittings. On average, the adjustments were smallest for the CAMREST procedure, slightly larger for the CAMEQ procedure, and largest of all for DSL [i/o]. For the DSL [i/o] the gain changes were mostly negative, especially for high frequencies and the higher input level. After these gain adjustments, users wore the aids for at least 3 weeks before speech reception thresholds (SRTs) for sentences in quiet and in steady and fluctuating background noise were measured. The APHAB questionnaire was also administered. The hearing aids were then refitted with the next procedure. SRTs and APHAB scores did not differ significantly between the three procedures. We conclude that the CAMEQ and CAMREST procedures provide a more appropriate initial fitting than DSL [i/o] for unilaterally experienced hearing aid wearers. Comparison with our earlier study based on bilateral fittings suggests that the preferred gains are similar for unilateral and bilateral fittings.

摘要

本文是比较三种多通道压缩式助听器初始验配程序系列论文中的第二篇。第一篇论文报告了一组10名有经验的双侧佩戴助听器用户的验配结果。本文报告了另一组10名有经验的单侧佩戴助听器用户的验配结果。这三种程序分别是:(1)CAMEQ,旨在放大言语信号,使500 - 5000赫兹频率范围内每个临界频带的响度相等,并在广泛的言语声级范围内使总体响度与正常情况相似;(2)CAMREST,旨在放大言语信号,以便在广泛的言语声级范围内恢复正常的特定响度模式;(3)DSL [i/o],旨在将听力正常者的动态范围映射到听力受损者缩小的动态范围内,同时完全恢复可听度。每个受试者依次使用三种验配程序中的每一种,佩戴一台Danalogic 163D数字助听器;验配程序的顺序在受试者之间进行了平衡。使用真耳测量法验证了55和80分贝声压级输入水平下的规定插入增益。在使用给定程序验配后以及验配1周后,必要时通过达到可接受验配所需的最小量来调整增益。平均而言,CAMREST程序的调整最小,CAMEQ程序稍大,而DSL [i/o]程序的调整最大。对于DSL [i/o],增益变化大多为负,尤其是高频和较高输入水平时。在进行这些增益调整后,用户佩戴助听器至少3周,然后测量安静环境、稳定和波动背景噪声中句子的言语接受阈值(SRT)。还进行了APHAB问卷调查。然后用下一种程序重新验配助听器。三种程序之间的SRT和APHAB得分没有显著差异。我们得出结论,对于单侧佩戴助听器有经验的用户,CAMEQ和CAMREST程序比DSL [i/o]提供了更合适的初始验配。与我们早期基于双侧验配的研究相比表明,单侧和双侧验配的优选增益相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验