O'Donnell R G, León Vintró L, Duffy G J, Mitchell P I
Molecular Imaging Institute (M2i), Blackrock Clinic, Blackrock, Co. Dublin, Ireland.
Appl Radiat Isot. 2004 Feb-Apr;60(2-4):539-42. doi: 10.1016/j.apradiso.2003.11.073.
The levels of residual radioactivity induced in Havar foils at the entrance of a high-pressure 18O-enriched water target used for the production of 18F- in a medical cyclotron with 16 MeV protons have been determined using high-resolution gamma-ray spectrometry. Whole body and skin dose rates arising from exposure to these foils during their periodic replacement have been estimated. The results indicate that irradiated foils do not represent a significant radiological hazard for the cyclotron operating staff and that no waste disposal difficulties should be encountered after an appropriate 'cooling' period of 2 years.