Individual control and quantification of phosphate removal is desirable in dialysis treatment. Currently, no on-line method exists to quantify phosphate removal. We demonstrate that a multivariate calibration model based on infrared transmission spectra is capable of predicting phosphate, urea, and glucose concentrations at clinically relevant levels. The on-line monitoring of these components by infrared spectroscopy is therefore feasible.

摘要

在透析治疗中,对磷酸盐清除进行个体化控制和定量是很有必要的。目前,尚无在线方法可对磷酸盐清除进行定量。我们证明,基于红外透射光谱的多元校准模型能够预测临床相关水平下的磷酸盐、尿素和葡萄糖浓度。因此,通过红外光谱对这些成分进行在线监测是可行的。