Spuentrup Elmar, Katoh Marcus, Buecker Arno, Manning Warren J, Schaeffter Tobias, Nguyen Trung-Hieu, Kühl Harald P, Stuber Matthias, Botnar Rene M, Günther Rolf W
Department of Diagnostic Radiology, University Hospital, Aachen University of Technology, Pauwelsstrasse 30, 52057 Aachen, Germany.
Radiology. 2004 May;231(2):581-6. doi: 10.1148/radiol.2312030451. Epub 2004 Mar 24.
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.
作者对16名健康成年人及4名初步研究患者进行了桡动脉稳态自由进动(SSFP)冠状动脉磁共振(MR)血管造影、笛卡尔k空间采样SSFP冠状动脉MR血管造影及梯度回波冠状动脉MR血管造影。采用带有T2预脉冲和笛卡尔k空间采样的标准梯度回波MR成像作为参考技术。通过主观运动伪影水平、客观对比噪声比及血管清晰度对图像质量进行比较。与笛卡尔SSFP及梯度回波MR血管造影相比,桡动脉SSFP可减少运动伪影并提高血管清晰度。笛卡尔SSFP导致运动伪影增加(P<.05)。桡动脉SSFP的对比噪声比低于笛卡尔SSFP,但与参考技术相似。由于血管边界清晰度提高,桡动脉SSFP冠状动脉MR血管造影似乎更具优势。