Sakai Takatoshi, Shinahara Katsura, Torimaru Akira, Tanaka Hiroyuki, Shoyama Yukihiro, Matsumoto Kiyoshi
Department of Bioscience and Biotechnology, Faculty of Agriculture, Kyushu University, Fukuoka 812-8581, Japan.
Anal Sci. 2004 Feb;20(2):279-83. doi: 10.2116/analsci.20.279.
A sensitive and selective determination of glycyrrhizin (GC) based on surface plasmon resonance (SPR) was performed by using an anti-GC monoclonal antibody (GC-MAb) and GC-bovine serum albumin (GC-BSA) conjugate (antigen). GC-BSA was immobilized on an Au thin film of the SPR sensor chip by physical adsorption, and GC determinations were performed by an indirect competitive method. The addition of GC into the GC-MAb solution (5 microg/ml) was found to decrease the incident-angle shift sharply because of an inhibition effect of GC. The RSDs (n = 3) of each point were less than 4%. The lowest detection limit for GC by SPR was almost the same as that by ELISA, 60-75 ng/ml. An evaluation of the affinity constant between GC-MAb and GC using the data from ELISA and those from SPR measurements was performed. The values of the association constant (KA) from three different analyses of ELISA data and from SPR measurements are discussed in detail. As a whole, the affinity constant (KA) between GC-MAb and GC was on the order of 10(7) M(-1).
基于表面等离子体共振(SPR),通过使用抗甘草酸单克隆抗体(GC-MAb)和甘草酸-牛血清白蛋白(GC-BSA)偶联物(抗原)对甘草酸(GC)进行了灵敏且选择性的测定。通过物理吸附将GC-BSA固定在SPR传感器芯片的金薄膜上,并采用间接竞争法进行GC测定。由于GC的抑制作用,发现向GC-MAb溶液(5微克/毫升)中加入GC会使入射角偏移急剧降低。各点的相对标准偏差(n = 3)小于4%。SPR对GC的最低检测限与酶联免疫吸附测定(ELISA)的几乎相同,为60 - 75纳克/毫升。利用ELISA数据和SPR测量数据对GC-MAb与GC之间的亲和常数进行了评估。详细讨论了来自ELISA数据的三种不同分析以及SPR测量的缔合常数(KA)值。总体而言,GC-MAb与GC之间的亲和常数(KA)约为10⁷ M⁻¹。