Small-dense low-density lipoprotein (SD-LDL) is associated with coronary heart disease risk. Current methods for its quantification are expensive, complex and time-consuming. Plasma was adjusted to a density (D) of 1.044 g/ml in a volume of 0.18 ml and centrifuged in a Beckman Airfuge at 160 000 x g for 3 h 7 min and apolipoprotein B (apoB) then determined in the infranatant. Results were compared with centrifugation of 5 ml of plasma at D = 1.044 g/ml at 144 000 x g for 18 h in a preparative ultracentrifuge (UC). We obtained blood samples from healthy subjects (n = 73) and from dyslipidaemic patients (n = 112). SD-LDL apoB levels as determined using the UC method ranged from 0.01-0.43 g/l and there was a good correlation with Airfuge results (r = 0.925; p < 0.0001; n = 185). There was a mean difference of 0.0125 g/l between methods. SD-LDL apoB levels as determined using the Airfuge showed a reasonable agreement with results obtained using density gradient ultracentrifugation (r = 0.773; p < 0.01; n = 12). Airfuge results correlated directly with triglyceride concentration, in both healthy men (r = 0.296; p < 0.05) and dyslipidaemic men (r = 0.520; p < 0.001) and also in dyslipidaemic women (r = 0.463; p < 0.005). Airfuge results correlated inversely with high-density lipoprotein-cholesterol (HDL-C) concentration, in both healthy men (r = -0.237; p < 0.05) and dyslipidaemic men (r = -0.293; p < 0.005). Using a micro-method, we obtained results which establish that the Airfuge provides a more rapid and less expensive method for quantification of SD-LDL.
小而密低密度脂蛋白(SD-LDL)与冠心病风险相关。目前对其进行定量的方法昂贵、复杂且耗时。将0.18 ml血浆调整至密度(D)为1.044 g/ml,在贝克曼空气离心机中以160 000×g离心3小时7分钟,然后测定下层清液中的载脂蛋白B(apoB)。将结果与在制备型超速离心机(UC)中以144 000×g将5 ml血浆在D = 1.044 g/ml下离心18小时的结果进行比较。我们从健康受试者(n = 73)和血脂异常患者(n = 112)中采集血样。使用UC方法测定的SD-LDL apoB水平范围为0.01 - 0.43 g/l,与空气离心机结果具有良好的相关性(r = 0.925;p < 0.0001;n = 185)。两种方法之间的平均差异为0.0125 g/l。使用空气离心机测定的SD-LDL apoB水平与使用密度梯度超速离心法获得的结果显示出合理的一致性(r = 0.773;p < 0.01;n = 12)。空气离心机结果与甘油三酯浓度直接相关,在健康男性(r = 0.296;p < 0.05)和血脂异常男性(r = 0.520;p < 0.001)以及血脂异常女性(r = 0.463;p < 0.005)中均如此。空气离心机结果与高密度脂蛋白胆固醇(HDL-C)浓度呈负相关,在健康男性(r = -0.237;p < 0.05)和血脂异常男性(r = -0.293;p < 0.005)中均如此。使用微量方法,我们获得的结果表明,空气离心机为SD-LDL的定量提供了一种更快速且成本更低的方法。