Suppr超能文献

对比增强三维肺灌注磁共振成像:1.0M钆布醇与0.5M钆喷酸葡胺在三个剂量水平的个体内比较

Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels.

作者信息

Fink Christian, Puderbach Michael, Ley Sebastian, Plathow Christian, Bock Michael, Zuna Ivan, Kauczor Hans-Ulrich

机构信息

Department of Radiology, Deutsches Krebsforschungszentrum (DKFZ), Innovative Krebsdiagnostik und Therapie, Heidelberg, Germany.

出版信息

Invest Radiol. 2004 Mar;39(3):143-8. doi: 10.1097/01.rli.0000101482.79137.f4.

Abstract

RATIONALE AND OBJECTIVES

To compare 1.0 M gadobutrol and 0.5 M Gd-DTPA for contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging (3D MRI).

MATERIALS AND METHODS

Ten healthy volunteers (3 females; 7 males; median age, 27 years; age range, 18-31 years) were examined with contrast-enhanced dynamic 3D MRI with parallel acquisition technique (FLASH 3D; reconstruction algorithm: generalized autocalibrating partially parallel acquisitions; acceleration factor: 2; TE/TR/alpha: 0.8/1.9 milliseconds/40 degrees; FOV: 500 x 375 mm; matrix: 256 x 86; slab thickness: 180 mm; 36 partitions; voxel size: 4.4 x 2 x 5 mm; TA: 1.48 seconds). Twenty-five consecutive data sets were acquired after intravenous injection of 0.025, 0.05, and 0.1 mmol/kg body weight of gadobutrol and Gd-DTPA. Quantitative measurements of peak signal-to-noise ratios (SNR) of both lungs were performed independently by 3 readers. Bolus transit times through the lungs were assessed from signal intensity time curves.

RESULTS

The peak SNR in the lungs was comparable between gadobutrol and Gd-DTPA at all dose levels (15.7 vs. 15.5 at 0.1 mmol/kg bw; 12.9 vs. 12.5 at 0.05 mmol/kg bw; 7.6 vs. 8.9 at 0.025 mmol/kg bw). A dose of 0.1 mmol/kg achieved the highest peak SNR compared with all other dose levels (P < 0.05). A higher peak SNR was observed in gravity dependent lung (P < 0.05). Despite different injection volumes, transit times of the contrast bolus did not differ between both agents.

CONCLUSION

Higher concentrated gadolinium chelates offer no advantage over standard 0.5 M Gd-DTPA for contrast-enhanced 3D MRI of lung perfusion.

摘要

原理与目的

比较1.0 M钆布醇和0.5 M钆喷酸葡胺用于对比增强三维肺灌注磁共振成像(3D MRI)的效果。

材料与方法

对10名健康志愿者(3名女性;7名男性;年龄中位数27岁;年龄范围18 - 31岁)采用对比增强动态3D MRI并行采集技术(快速小角度激发3D;重建算法:广义自校准部分并行采集;加速因子:2;回波时间/重复时间/翻转角:0.8/1.9毫秒/40度;视野:500×375毫米;矩阵:256×86;层厚:180毫米;36个分区;体素大小:4.4×2×5毫米;采集时间:1.48秒)进行检查。静脉注射0.025、0.05和0.1 mmol/kg体重的钆布醇和钆喷酸葡胺后,连续采集25组数据集。由3名阅片者独立对双肺的峰值信噪比(SNR)进行定量测量。通过信号强度时间曲线评估对比剂团注通过肺部的时间。

结果

在所有剂量水平下钆布醇和钆喷酸葡胺在肺部的峰值SNR相当(0.1 mmol/kg体重时为15.7对15.5;0.05 mmol/kg体重时为12.9对12.5;0.025 mmol/kg体重时为7.6对8.9)。与所有其他剂量水平相比,0.1 mmol/kg的剂量达到最高峰值SNR(P < 0.05)。重力依赖肺中观察到更高的峰值SNR(P < 0.05)。尽管注射体积不同,但两种对比剂的团注通过时间并无差异。

结论

对于肺灌注对比增强3D MRI,高浓度钆螯合物相较于标准的0.5 M钆喷酸葡胺并无优势。