Random-zero sphygmomanometer, Rose's tape, and the accuracy of the blood pressure measurements in children.

作者信息

Nuutinen M, Turtinen J, Uhari M

机构信息

Department of Pediatrics, University of Oulu, Finland.

出版信息

Pediatr Res. 1992 Aug;32(2):243-7. doi: 10.1203/00006450-199208000-00023.

DOI:10.1203/00006450-199208000-00023
PMID:1508618
Abstract

In the Cardiovascular Risk in Young Finns project, blood pressure (BP) was measured in 3549 randomly selected children aged 6-18 y in 1980, and 2887 and 2500 of the same individuals in 1983 and 1986, respectively. An ordinary mercury sphygmomanometer (OMS) was used in the first two surveys and a random-zero sphygmomanometer (RZS) in the third survey. Systolic and diastolic BP were lower when measured with an RZS than with an OMS and the shape of the age-related BP curve obtained with an RZS was significantly different from that obtained with an OMS, because low BP values were apparently measured more accurately with the former. Use of the RZS did not affect the distribution of the BP values. Rose's tape readings were used to evaluate the effect of training and to control the accuracy of the BP measurements. According to Rose's tape readings, Korotkoff's 4th phase BP was more difficult to measure accurately than 5th phase (p = 0.002). The mean values for the differences between the correct and actual BP readings on the Rose's tape were -1.2 mm Hg (SD 2.1) for systolic BP, 8.3 mm Hg (SD 13.6) for diastolic Korotkoff's 4th phase BP, and 1.2 mm Hg (SD 7.0) for diastolic Korotkoff's 5th phase BP, with a negative value indicating that the BP phase was measured lower than the correct value. Terminal digit preference was present in each survey to such an extent that it could have hampered the reaching of reliable conclusions from the data obtained with an OMS. The bias caused by terminal digit preference was obviated by the RZS.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Random-zero sphygmomanometer, Rose's tape, and the accuracy of the blood pressure measurements in children.
Pediatr Res. 1992 Aug;32(2):243-7. doi: 10.1203/00006450-199208000-00023.
2
A meta-analytical approach to the pooling of blood pressure values in children.一种汇总儿童血压值的荟萃分析方法。
Arctic Med Res. 1996 Jul;55(3):107-17.
3
Hawksley random zero sphygmomanometer versus the standard sphygmomanometer: an investigation of mechanisms.
J Hum Hypertens. 1995 Jul;9(7):571-3.
4
Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice?随机零位血压计与自动振荡式血压监测仪;哪一种是首选仪器?
J Hum Hypertens. 1995 Nov;9(11):885-9.
5
Investigation of end-digit preference in blood pressure records of hospitalized chinese patients and analysis of risk factors.调查住院中国患者血压记录中的末位数字偏好及危险因素分析。
Postgrad Med. 2012 Mar;124(2):53-7. doi: 10.3810/pgm.2012.03.2536.
6
Does the Hawksley random zero sphygmomanometer underestimate blood pressure, and by how much?霍克斯利随机零位血压计是否会低估血压,以及低估多少?
J Hum Hypertens. 1995 May;9(5):337-43.
7
Evaluation of the measurement of children's blood pressure in an epidemiological multicentre study.一项多中心流行病学研究中儿童血压测量的评估
Acta Paediatr Scand Suppl. 1985;318:79-88. doi: 10.1111/j.1651-2227.1985.tb10084.x.
8
Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanometer in children.三种示波法血压测量设备在儿童中相对于听诊法汞柱血压计的验证。
Blood Press Monit. 2006 Oct;11(5):281-91. doi: 10.1097/01.mbp.0000209082.09623.b4.
9
Comparison of Dinamap PRO-100 and mercury sphygmomanometer blood pressure measurements in a population-based study.基于人群的研究中 Dinamap PRO - 100 与汞柱式血压计血压测量结果的比较。
Am J Hypertens. 2006 Apr;19(4):353-60. doi: 10.1016/j.amjhyper.2005.10.020.
10
A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor.完美替代水银血压计:混合血压计的案例。
J Hum Hypertens. 2012 Apr;26(4):220-7. doi: 10.1038/jhh.2011.77. Epub 2011 Sep 8.