Bowers Emma J, Murray Alan
Regional Medical Physics Dept., Freeman Hospital, Newcastle upon Tyne, NE7 7DN, UK.
Clin Auton Res. 2004 Apr;14(2):92-8. doi: 10.1007/s10286-004-0169-z.
This study assessed the interaction between cardiac beat-to-beat interval changes and systolic pressure (SP) changes. Twenty subjects breathed regularly following displayed breathing signals at 4, 6, 8, 10, 12 and 14 breaths per minute, each for 5 minutes. ECG, non-invasive blood pressure (Finapres) and respiration waveforms were recorded. Time offsets between the cyclic patterns of RR-interval and SP changes were calculated. Displayed breathing signals were well followed; the mean correlation between displayed and recorded breathing signals ranged from 0.72 to 0.86. The time offset between RR-interval peaks and subsequent SP troughs decreased with increasing respiration rate, 3.8 +/- 1.7 s, 3.5 +/- 0.7 s, 3.1 +/- 0.6 s, 2.6 +/- 0.4 s, 2.3 +/- 0.4 s and 2.0 +/- 0.4 s mean +/- SD at 4, 6, 8, 10, 12 and 14 breaths per minute respectively. The relationship between mean time offset and frequency was significant (p < 0.001), with a 95% prediction interval of +/- 0.24 s. Published data showed no relationship between time offset and frequency, with a 95% prediction interval of +/- 2.8 s. However, when the offset definition proposed in this research was applied to these data, a significant relationship (p < 0.01) was evident, with a 95% prediction interval of +/- 1.5 s. In conclusion, apparently contradictory previous findings achieve good consensus when a standardized method for presenting results is applied. A delay exists between RR-interval and blood pressure changes, and this delay varies with breathing frequency.
本研究评估了逐搏心搏间期变化与收缩压(SP)变化之间的相互作用。20名受试者按照每分钟4、6、8、10、12和14次呼吸的显示呼吸信号进行规律呼吸,每种呼吸频率持续5分钟。记录心电图、无创血压(Finapres)和呼吸波形。计算RR间期和SP变化的周期性模式之间的时间偏移。受试者对显示的呼吸信号遵循良好;显示的呼吸信号与记录的呼吸信号之间的平均相关性在0.72至0.86之间。RR间期峰值与随后的SP谷值之间的时间偏移随呼吸频率增加而减小,在每分钟4、6、8、10、12和14次呼吸时,平均±标准差分别为3.8±1.7秒、3.5±0.7秒、3.1±0.6秒、2.6±0.4秒、2.3±0.4秒和2.0±0.4秒。平均时间偏移与频率之间的关系具有显著性(p<0.001),95%预测区间为±0.24秒。已发表的数据显示时间偏移与频率之间无关系,95%预测区间为±2.8秒。然而,当将本研究中提出的偏移定义应用于这些数据时,明显存在显著关系(p<0.01),95%预测区间为±1.5秒。总之,当应用标准化的结果呈现方法时,先前明显矛盾的研究结果达成了良好的共识。RR间期和血压变化之间存在延迟,且这种延迟随呼吸频率而变化。