Eyelid position measurement in Graves' ophthalmopathy: reliability of a photographic technique and comparison with a clinical technique.

作者信息

Edwards Douglas T, Bartley George B, Hodge David O, Gorman Colum A, Bradley Elizabeth A

机构信息

Department of Ophthalmology, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA.

出版信息

Ophthalmology. 2004 May;111(5):1029-34. doi: 10.1016/j.ophtha.2003.08.027.

Abstract

PURPOSE

To evaluate intraobserver reliability and interobserver reliability of a computer-based digital image measurement of eyelid position in Graves' ophthalmopathy and to compare digital image measurement with clinical measurement.

DESIGN

Cross-sectional study.

PARTICIPANTS

Eighty-four eyes of 42 patients with mild to moderate bilateral Graves' ophthalmopathy.

METHODS

Digital images were created from 35-mm color slides of both eyes of participants and projected onto a 15-inch flat-screen computer monitor. Three observers (2 oculoplastic surgeons and 1 ophthalmology resident) independently recorded eyelid fissure height, margin-reflex distance, and inferior scleral show for each eye.

MAIN OUTCOME MEASURES

Intraobserver reliability and interobserver reliability of eyelid parameter measurements, as described by the intraclass correlation coefficient (ICC) and Bland-Altman plots. Agreement between digital image measurements of the investigators and clinical measurements taken on the same day as the photographs also was assessed.

RESULTS

Excellent intraobserver agreement was found for the measurement of all eyelid parameters for all 3 investigators (ICC range, 0.93-0.99). Interobserver agreement for all eyelid parameters was also excellent for all investigators (ICC, 0.86-0.97). Agreement between the photographic and clinical measurements for eyelid parameters was fair to moderate (ICC range, 0.38-0.62).

CONCLUSION

Measurement of several eyelid parameters in Graves' ophthalmopathy patients from computer-based digital images is reliable. Associations between photographic and clinical measurements for all parameters are weaker. Relative to clinical measurements, the photographic technique offers the advantages of potential for masking and ease of transmission that might be useful in clinical trials.

摘要

目的

评估基于计算机的数字图像测量Graves眼病眼睑位置的观察者内可靠性和观察者间可靠性,并将数字图像测量与临床测量进行比较。

设计

横断面研究。

参与者

42例轻度至中度双侧Graves眼病患者的84只眼。

方法

从参与者双眼的35毫米彩色幻灯片创建数字图像,并投影到15英寸平板计算机显示器上。三名观察者(2名眼整形外科医生和1名眼科住院医师)独立记录每只眼睛的睑裂高度、边缘反射距离和下巩膜暴露情况。

主要观察指标

用组内相关系数(ICC)和Bland-Altman图描述眼睑参数测量的观察者内可靠性和观察者间可靠性。还评估了研究者的数字图像测量与拍摄当天进行的临床测量之间的一致性。

结果

所有3名观察者对所有眼睑参数的测量均发现了极好的观察者内一致性(ICC范围为0.93-0.99)。所有观察者对所有眼睑参数的观察者间一致性也极好(ICC为0.86-0.97)。眼睑参数的摄影测量与临床测量之间的一致性为中等(ICC范围为0.38-0.62)。

结论

基于计算机数字图像测量Graves眼病患者的几个眼睑参数是可靠的。所有参数的摄影测量与临床测量之间的相关性较弱。相对于临床测量,摄影技术具有潜在的掩盖优势和易于传输的优点,这在临床试验中可能有用。