Suppr超能文献

喉罩与麻醉废气暴露

Laryngeal mask and anaesthetic waste gas exposure.

作者信息

Lambert-Jensen P, Christensen N E, Brynnum J

机构信息

Division of Anaesthesia, Hjørring Sygehus, Denmark.

出版信息

Anaesthesia. 1992 Aug;47(8):697-700. doi: 10.1111/j.1365-2044.1992.tb02395.x.

Abstract

In recent years there has been a growing awareness of the possible hazards caused by anaesthetic gases in operating theatres. The laryngeal mask airway provides an alternative both to tracheal intubation and the face mask although the implications for operating theatre contamination have not been quantified. This paper describes the incidence and magnitude of exposure of theatre personnel to waste anaesthetic gases during laryngeal mask airway anaesthesia. The leakage of anaesthetic gases to the anaesthetist's breathing zone was monitored using a Bruel & Kjaer Multi Gas Monitor, Type 1302 during 50 general anaesthetics employing either spontaneous (n = 24) or controlled (n = 26) ventilation. All patients were anaesthetised with propofol, alfentanil and nitrous oxide. There was no statistically significant association between the amount of anaesthetic gas leakage and ventilation method. The laryngeal mask airway meets occupational safety requirements on nitrous oxide concentrations in the operating theatre environment.

摘要

近年来,人们越来越意识到手术室中麻醉气体可能造成的危害。喉罩气道为气管插管和面罩提供了一种替代方法,尽管其对手术室污染的影响尚未量化。本文描述了在喉罩气道麻醉期间手术室人员接触废麻醉气体的发生率和程度。在50例采用自主通气(n = 24)或控制通气(n = 26)的全身麻醉过程中,使用Bruel & Kjaer 1302型多气体监测仪监测麻醉气体向麻醉医生呼吸区域的泄漏情况。所有患者均使用丙泊酚、阿芬太尼和氧化亚氮进行麻醉。麻醉气体泄漏量与通气方法之间无统计学显著关联。喉罩气道符合手术室环境中氧化亚氮浓度的职业安全要求。