Suppr超能文献

GSB III型全肘关节置换术的5至13年随访

Five- to thirteen-year follow-up of the GSB III total elbow arthroplasty.

作者信息

Kelly Edward W, Coghlan Jennifer, Bell Simon

机构信息

Minnesota Orthopedic Specialists, Minneapolis, MN 55454, USA.

出版信息

J Shoulder Elbow Surg. 2004 Jul-Aug;13(4):434-40. doi: 10.1016/j.jse.2004.01.028.

Abstract

Between 1988 and 1995, the senior author performed total elbow arthroplasty in 28 elbows (23 patients) with the GSB III prosthesis. At the most recent follow-up, 7 patients had died (9 elbows) and 1 had the implant removed because of a deep infection. The remaining 18 elbows (15 patients) were available for clinical and radiographic review at a mean period of 7.6 years (range, 5.5-11.9 years). All 15 patients were satisfied with the results of their elbow replacement, with a mean Mayo elbow performance score of 91 (range, 75-100). The mean flexion/extension and supination/pronation arcs improved by 33 degrees and 67 degrees, respectively. Radiographic follow-up demonstrated progressive loosening in only 1 patient and no progressive loosening in those with an adequate cement technique. Mild or moderate lysis of the distal humeral or proximal ulnar components was noted in 10 elbows, and severe lysis of the distal humerus was seen in 1. Of the patients, 6 (21%) had mild complications: triceps avulsions in 3, superficial wound infections in 2, and an undisplaced fracture of the distal humeral medial condyle in 1. In 4 patients (14%) complications developed requiring reoperation, including exchange of the polyethylene bushing because of wear, debridement of synovitis, resection arthroplasty for deep infection, and exploration of an ulnar nerve palsy. In 2 additional patients (7%), persistent ulnar nerve paresthesias developed postoperatively. Of the 28 elbow replacements performed with the GSB III prosthesis, only 1 required revision because of loosening at a mean follow-up of 7.6 years. The results of this series of GSB III elbow replacements in patients with rheumatoid arthritis demonstrate reasonable survivorship of this prosthesis.

摘要

1988年至1995年间,资深作者使用GSB III型假体对28例肘部(23例患者)进行了全肘关节置换术。在最近一次随访时,7例患者(9个肘部)已死亡,1例因深部感染取出了植入物。其余18个肘部(15例患者)可用于临床和影像学检查,平均随访时间为7.6年(范围为5.5 - 11.9年)。所有15例患者对肘关节置换结果均满意,Mayo肘关节功能评分平均为91分(范围为75 - 100分)。平均屈伸和旋前/旋后弧度分别改善了33度和67度。影像学随访显示仅1例患者出现假体渐进性松动,而采用合适骨水泥技术的患者未出现渐进性松动。10个肘部可见肱骨远端或尺骨近端假体轻度或中度溶解,1个肘部可见肱骨远端严重溶解。6例患者(21%)出现轻度并发症:3例肱三头肌撕脱,2例表浅伤口感染,1例肱骨远端内侧髁无移位骨折。4例患者(14%)出现需要再次手术的并发症,包括因磨损更换聚乙烯衬套、滑膜清创、深部感染的切除性关节成形术以及尺神经麻痹探查。另外2例患者(7%)术后出现持续性尺神经感觉异常。在使用GSB III型假体进行的28例肘关节置换中,平均随访7.6年时仅1例因松动需要翻修。这一系列类风湿关节炎患者使用GSB III型肘关节置换的结果表明该假体具有合理的生存率。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验