Baek N K, Sung I H, Kim D E
Department of Mechanical Engineering, Yonsei University, Seoul, Korea.
Proc Inst Mech Eng H. 2004;218(3):193-201. doi: 10.1243/095441104323118914.
The design of the capsule body for a self-propelled endoscope is important from the frictional resistance point of view. The motivation of this work was to gain a better understanding of the effect of capsule shape on the frictional resistance of the capsule inside a small intestine. Special experimental set-ups were built to investigate the frictional resistance of the capsule and the viscoelastic deformation characteristics of the small intestine specimen of a pig. Tests were performed with capsules of various shapes and dimensions. Experimental data showed that a smooth cylindrical capsule geometry resulted in the least frictional resistance due to the shape and relatively small surface area. Also, it was found that the variation of frictional resistance of the capsule was closely related to the local change in the viscoelastic property of the intestine due to the heterogeneity of the internal structure of the intestine.
从摩擦阻力的角度来看,自推进式内窥镜胶囊主体的设计至关重要。这项工作的目的是更好地了解胶囊形状对小肠内胶囊摩擦阻力的影响。搭建了专门的实验装置来研究胶囊的摩擦阻力以及猪小肠标本的粘弹性变形特性。对各种形状和尺寸的胶囊进行了测试。实验数据表明,由于形状和相对较小的表面积,光滑的圆柱形胶囊几何形状产生的摩擦阻力最小。此外,还发现由于肠道内部结构的不均匀性,胶囊摩擦阻力的变化与肠道粘弹性特性的局部变化密切相关。