Suzuki Satoshi, Humayun Mark S, Weiland James D, Chen Shih-Jen, Margalit Eyal, Piyathaisere Duke V, de Juan Eugene
Wilmer Ophthalmological Institute, Johns Hopkins University, Baltimore, MD, USA.
Jpn J Ophthalmol. 2004 Jul-Aug;48(4):345-9. doi: 10.1007/s10384-004-0084-9.
To compare the threshold for electrically elicited action potentials of retinal ganglion cells in normal mouse retina and photoreceptor degenerated (rd) mouse retina.
Microelectrode recordings were made from retinal ganglion cells of normal and rd mice. Mice with a genetically based retinal degeneration (rd mice) were grown to the age of 16 weeks, when light-evoked responses could no longer be recorded. A bare wire was placed in the vitreous to stimulate the retina with charge-balanced current pulses. The following pulse shapes were investigated: single, square biphasic pulse, single sine wave, and biphasic pulse trains.
Normal mice had significantly lower stimulus thresholds than rd mice for all pulse shapes. In normal and rd mice, short pulses were more efficient with respect to total charge used, but required a higher current. In normal mice, sine wave stimulation was significantly more efficient than a biphasic pulse of the same duration. No difference was noted between sine wave and square wave stimulation in rd mice. Pulse trains offered little benefit over single pulses.
The amount of electrical charge required to elicit an action potential is dependent on the condition of the retina and the shape of the stimulus pulse used to deliver the charge.
比较正常小鼠视网膜和光感受器退化(rd)小鼠视网膜中视网膜神经节细胞电诱发动作电位的阈值。
从正常和rd小鼠的视网膜神经节细胞进行微电极记录。具有遗传性视网膜退化的小鼠(rd小鼠)饲养至16周龄,此时不再能记录到光诱发反应。将一根裸线置于玻璃体内,用电荷平衡电流脉冲刺激视网膜。研究了以下脉冲形状:单个方波双相脉冲、单个正弦波和双相脉冲串。
对于所有脉冲形状,正常小鼠的刺激阈值显著低于rd小鼠。在正常和rd小鼠中,短脉冲在总电荷使用方面更有效,但需要更高的电流。在正常小鼠中,正弦波刺激比相同持续时间的双相脉冲显著更有效。在rd小鼠中,正弦波和方波刺激之间未观察到差异。脉冲串与单个脉冲相比益处不大。
诱发动作电位所需的电荷量取决于视网膜的状况以及用于传递电荷的刺激脉冲的形状。