Horwacik T, Bilski P, Olko P, Spurny F, Turek K
Institute of Nuclear Physics, Radzikowskiego 152, 31-342 Kraków, Poland.
Radiat Prot Dosimetry. 2004;110(1-4):377-80. doi: 10.1093/rpd/nch132.
Measurements of cosmic radiation dose rates (from the neutron and the non-neutron components) on board passenger aircraft were performed using environmental packages with thermoluminescent TL and CR-39 etched track detectors. The packages were calibrated at the CERN-EU high-energy Reference Field Facility and evaluated at the Institute of Nuclear Physics in Krakow (TL + CR-39) and at the German Aerospace Centre in Cologne (CR-39). Detector packages were exposed on board passenger aircraft operated by LOT Polish Airlines, flown between February and May 2001. The values of effective dose rate determined, averaged over the measuring period, ranged between 2.9 and 4.4 microSv h(-1). The results of environmental measurements agreed to within 10% with values calculated from the CARI-6 code.