[门控心肌灌注单光子发射计算机断层扫描测量左心室功能的可重复性及与血池放射性核素心室造影的比较]

[Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography].

作者信息

Castell-Conesa Joan, Aguadé-Bruix Santiago, García-Burillo Amparo, González José M, Canela Teresa, Oller Guillermo, Díez María J, Roca Isabel, Candell-Riera Jaume

机构信息

Servicio de Medicina Nuclear, Hospital Universitari Vall d'Hebron, Barcelona, Spain.

出版信息

Rev Esp Cardiol. 2004 Oct;57(10):931-8.

Abstract

INTRODUCTION AND OBJECTIVE

This study was designed to evaluate the reproducibility of ejection fraction (EF) and ventricular volume measurements obtained with single photon emission computed tomography (gated-SPECT), and to assess the correlation between EF values obtained with this method and blood pool planar radionuclide ventriculography.

PATIENTS AND METHOD

A total of 55 patients were included (37 men, mean age 61.3 years) upon referral to two nuclear cardiology units for diagnosis (50%) or follow-up of known coronary artery disease. In a standard 2-day protocol, patients received a dose of [99mTc]tetrofosmin (800 MBq) at stress and at rest. Two resting gated-SPECT studies were performed. QGS software was used to obtain left ventricular EF, end-diastolic volume (EDV) and end-systolic volume (ESV). Forty-nine patients agreed to undergo blood pool ventriculography on the third day.

RESULTS

Interobserver variability was 0.5 (2.6)% (r=0.99) for EF, 1.9 (10.7) mL for EDV (r=0.98) and 0.5 (5.4) mL for ESV (r=0.99). Interassay variability was 2 (5.1)% (r=0.94) for EF, 4.5 (8.6) mL for EDV (r=0.99) and 3.4 (6.6) mL for ESV (r=0.99). The correlation between gated-SPECT EF and blood pool EF was suboptimal (r=0.75, 95%CI, 0.59-0.85).

CONCLUSIONS

There was excellent interobserver and interassay reproducibility for left ventricular functional parameters measured with gated-SPECT and QGS software, and this method can be used for serial evaluations of ventricular function. Although the correlation between values obtained with gated-SPECT and blood pool ventriculography was acceptable, the differences show that the two techniques cannot be considered equivalent.

摘要

引言与目的

本研究旨在评估单光子发射计算机断层扫描(门控SPECT)获得的射血分数(EF)和心室容积测量值的可重复性,并评估该方法获得的EF值与血池平面放射性核素心室造影之间的相关性。

患者与方法

共有55例患者(37例男性,平均年龄61.3岁)因诊断(50%)或已知冠状动脉疾病的随访转诊至两个核心脏病科。在标准的为期2天的方案中,患者在负荷和静息状态下接受一剂[99mTc]替曲膦(800MBq)。进行了两次静息门控SPECT研究。使用QGS软件获得左心室EF、舒张末期容积(EDV)和收缩末期容积(ESV)。49例患者同意在第三天进行血池心室造影。

结果

EF的观察者间变异性为0.5(2.6)%(r=0.99),EDV为1.9(10.7)mL(r=0.98),ESV为0.5(5.4)mL(r=0.99)。测定间变异性为EF 2(5.1)%(r=0.94),EDV为4.5(8.6)mL(r=0.99),ESV为3.4(6.6)mL(r=0.99)。门控SPECT EF与血池EF之间的相关性欠佳(r=0.75,95%CI,0.59 - 0.85)。

结论

使用门控SPECT和QGS软件测量左心室功能参数具有出色的观察者间和测定间可重复性,该方法可用于心室功能的系列评估。尽管门控SPECT与血池心室造影获得的值之间的相关性尚可,但差异表明这两种技术不能视为等效。