Cull D L, Gregory R T, Wheeler J R, Snyder S O, Gayle R G, Parent F N
Division of Vascular and Transplant Surgery, Eastern Virginia Medical School, Norfolk 23510.
Ann Vasc Surg. 1992 Jan;6(1):20-4. doi: 10.1007/BF02000662.
Duplex scan, arteriography, and graft flow rates were used intraoperatively to assess 56 infrainguinal arterial reconstructions for technical error. Intraoperative duplex scan identified a technical defect or low graft flow velocity in 22 of 56 (39%) grafts. Eleven of the defects were judged to be clinically significant and were corrected. Four of these defects were missed by the completion arteriogram. One technical defect identified by completion arteriography was missed by duplex scan. Fifty percent (5/10) of grafts with an abnormal intraoperative duplex scan which were not corrected occluded within 30 days. Graft flow rates measured by the electromagnetic flowmeter were neither predictive of technical defect nor early graft outcome. Although the sensitivity of arteriography and duplex scan (88% sensitivity for both) were both high for predicting early graft occlusion, the combination of duplex scan and completion arteriography was significantly more accurate (p less than .0001) in predicting early graft outcome than either study alone. Duplex scan identified significant graft defects which were not detected by completion arteriography or graft flow rate measurement. The duplex scan also provided hemodynamic information which was predictive of early graft outcome. The duplex scan can be an important adjunct to completion arteriography for the intraoperative assessment of infrainguinal arterial reconstruction.
术中使用双功超声扫描、动脉造影和移植物血流速率来评估56例腹股沟下动脉重建手术的技术失误情况。术中双功超声扫描在56例移植物中的22例(39%)中发现了技术缺陷或移植物血流速度较低。其中11处缺陷被判定具有临床意义并得到了纠正。其中4处缺陷在完成动脉造影时未被发现。双功超声扫描漏诊了完成动脉造影时发现的1处技术缺陷。术中双功超声扫描异常但未得到纠正的移植物中,有50%(5/10)在30天内发生了闭塞。用电磁流量计测量的移植物血流速率既不能预测技术缺陷,也不能预测移植物早期转归。虽然动脉造影和双功超声扫描的敏感度(两者均为88%)在预测移植物早期闭塞方面都很高,但双功超声扫描和完成动脉造影相结合在预测移植物早期转归方面比单独的任何一项检查都显著更准确(p小于0.0001)。双功超声扫描发现了完成动脉造影或移植物血流速率测量未检测到的显著移植物缺陷。双功超声扫描还提供了可预测移植物早期转归的血流动力学信息。双功超声扫描可作为完成动脉造影的重要辅助手段,用于术中评估腹股沟下动脉重建情况。