Suppr超能文献

Intraoperative duplex scanning of arterial reconstructions: fate of repaired and unrepaired defects.

作者信息

Bandyk D F, Mills J L, Gahtan V, Esses G E

机构信息

Department of Surgery, University of South Florida College of Medicine,Tampa.

出版信息

J Vasc Surg. 1994 Sep;20(3):426-32; discussion 432-3. doi: 10.1016/0741-5214(94)90142-2.

Abstract

PURPOSE

Because unrecognized lesions can cause an arterial reconstruction to fail, duplex ultrasonography was evaluated as an intraoperative aid to assess technical adequacy and provide criteria for which lesions should be repaired immediately versus safely followed.

METHODS

Since 1990 intraoperative color duplex scanning(7 to 10 MHz linear array probe, pulsed-wave Doppler test spectrum analysis) was used to assess the frequency and severity of residual lesions in 368 patients after carotid endarterectomy (n = 210), infrainguinal vein bypass (n=135) or visceral/renal reconstruction (n = 23). Duplex scan results were categorized as normal or abnormal, with immediate repair of lesions demonstrating both lumen reduction and severe focal flow abnormalities (peak systolic velocity [Vp] > 150 to 180 cm/sec;velocity ratio [Vr] > 2.4). Arteriography was also performed in 81% of lower limb bypass procedures.

RESULTS

Duplex scanning identified technical (residual plaque, stricture) or intrinsic defects (platelet thrombus, distal thrombosis) requiring revision in 37 (10%) of the reconstructions. Infrainguinal bypass had the highest incidence of corrected defects (14%) and adverse events (3%). No adverse events occurred in patients with normal duplex scan results or after carotid endarterectomy. Overall, 76% of identified defects were corrected (carotid, 17 of 24; infrainguinal bypass, 19 of 24; visceral bypass, 1 of 1). Unrepaired flow defects (Vp = 150 to 190 cm/sec; Vr = 1.8 to 2.5) led to one graft occlusion and three early revisions. Postoperative duplex scanning demonstrated residual stenosis in seven of 12 patients with unrepaired defects, two of 36 patients with repaired defects, and five of 312 patients with normal scan results (p < 0.001).

CONCLUSION

Based on the types of lesions corrected and the low (< 0.5%) complication rate after a normal or modified arterial reconstruction, duplex scanning was found to be a valuable intraoperative aid. Unrepaired defects require close surveillance for progression.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验