化学消毒剂对经机械和化学抛光处理的热固化丙烯酸树脂横向强度的影响。

Effect of chemical disinfectants on the transverse strength of heat-polymerized acrylic resins submitted to mechanical and chemical polishing.

作者信息

Orsi Iara Augusta, Andrade Vanessa Gomes

机构信息

Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil.

出版信息

J Prosthet Dent. 2004 Oct;92(4):382-8. doi: 10.1016/j.prosdent.2004.07.015.

Abstract

STATEMENT OF PROBLEM

Immersion in chemical solutions used for cleansing and disinfecting prostheses can decrease the strength of denture base resins, making them more prone to fracture during use.

PURPOSE

The purpose of this study was to assess the effect of immersion in different chemical disinfectants for varying time periods on the transverse strength of 3 mechanically or chemically polished heat-polymerized acrylic resins.

MATERIAL AND METHODS

A total of 630 rectangular specimens (65 x 10 x 3 mm), 210 per resin (Classico, Lucitone 550, and QC-20), were fabricated. One side of each specimen was not polished and the other was either mechanically (n=300) or chemically (n=300) polished, and immersed for 10, 20, 30, 45, or 60 minutes in either 1%, 2.5%, or 5.25% sodium hypochlorite or 2% glutaraldehyde. Mechanically polished (n=15) and chemically polished (n=15) control specimens were immersed only in distilled water. The transverse strength (N/mm 2 ) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t test. Multiple comparisons were performed using Tukey and Scheffe tests (alpha=.05).

RESULTS

There was significant difference (P < .01) between types of polishing, with chemical polishing resulting in lower transverse strength. ANOVA identified significant differences (P < .01) in strength between mechanically polished Lucitone 550 and QC-20, and among all 3 chemically polished resins. No significant differences were observed between resins submitted to both types of polishing or between different immersion periods (10 to 60 minutes), disinfectants, or interaction.

CONCLUSIONS

Lucitone 550 resin presented the greatest transverse strength values with both types of polishing. Among the mechanically and chemically polished specimens, transverse strength was not affected after immersion in the disinfectants for the immersion periods tested (10 to 60 minutes). Chemically polished control and experimental (immersed in all solutions) QC-20 specimens showed significant differences in transverse strength values.

摘要

问题陈述

将假牙浸泡在用于清洁和消毒的化学溶液中会降低义齿基托树脂的强度,使其在使用过程中更容易断裂。

目的

本研究的目的是评估将三种机械或化学抛光的热聚合丙烯酸树脂在不同化学消毒剂中浸泡不同时间段对其横向强度的影响。

材料与方法

共制作630个矩形试件(65×10×3mm),每种树脂210个(Classico、Lucitone 550和QC - 20)。每个试件的一侧不抛光,另一侧进行机械抛光(n = 300)或化学抛光(n = 300),并分别在1%、2.5%或5.25%的次氯酸钠溶液或2%的戊二醛溶液中浸泡10、20、30、45或60分钟。机械抛光(n = 15)和化学抛光(n = 15)的对照试件仅浸泡在蒸馏水中。在万能试验机上以5mm/min的十字头速度测试横向强度(N/mm²)直至试件破坏。数据采用双向方差分析和学生t检验进行统计学分析。使用Tukey和Scheffe检验进行多重比较(α = 0.05)。

结果

抛光类型之间存在显著差异(P < 0.01),化学抛光导致较低的横向强度。方差分析表明,机械抛光的Lucitone 550和QC - 20之间以及所有三种化学抛光树脂之间的强度存在显著差异(P < 0.01)。在接受两种抛光类型的树脂之间,或在不同浸泡时间(10至60分钟)、消毒剂或相互作用之间未观察到显著差异。

结论

Lucitone 550树脂在两种抛光类型下均呈现出最高的横向强度值。在机械抛光和化学抛光的试件中,在所测试的浸泡时间(10至60分钟)内浸泡在消毒剂中后,横向强度不受影响。化学抛光的对照试件和实验(浸泡在所有溶液中)QC - 20试件的横向强度值存在显著差异。