Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters?

作者信息

Pesudovs Konrad, Marsack Jason D, Donnelly William J, Thibos Larry N, Applegate Raymond A

机构信息

Visual Optics Institute, College of Optometry, University of Houston, Houston, TX 77204-2020, USA.

出版信息

J Refract Surg. 2004 Sep-Oct;20(5):S508-14.

Abstract

PURPOSE

To develop single-valued wavefront aberration metrics that correlate strongly with visual performance. The purpose of this study is to explore whether photopic high contrast visual acuity (VA) is an appropriate visual performance reference and whether mesopic and/or low contrast testing provides any advantage.

METHODS

Subjects from the Texas Investigation of Cataract Optics study (N = 148) ranged in age from 21.6 to 83.8 years and from clear lens to dense nuclear cataract. Visual acuity was measured under four conditions: photopic high (VA(PHC)) and low (VA(PLC)) contrast, mesopic high (VA(MHC)) and low (VA(MLC)) contrast (photopic = 280 cd/m(2), mesopic = 0.75 cd/m(2)). Variables were tested for compliance with normality (-2.00 < skew and kurtosis < 2.00) and transformed if required. Linear regression and Bland-Altman 95% limits of agreement (+/-1.96 SD) were used to examine relationships between VA variables and between VA and wavefront aberration metrics.

RESULTS

The two photopic measures VA(PHC) (skew = 2.57, kurtosis = 12.2) and VA(PLC) (1.67, 5.41) were poorly distributed, but the two mesopic measures VA(MHC) (0.88, 1.67) and VA(MLC) (0.29, -0.18) were normally distributed. Strong correlations existed between the (transformed) VA variables (R: 0.53 to 0.84). However, limits of agreement ranged over 0.30 to 0.42 logMAR, whereas retest data suggested a range of 0.15. All four were offered in stepwise multiple linear regression for 30 wavefront metrics: 20 included VA(MLC) alone, two included VA(PLC), two included VA(MHC) and six included both VA(MLC) and VA(MHC); R(2) averaged 25%.

CONCLUSION

Although strongly correlated, low contrast and/or mesopic VA testing provides different information. Wave aberration metrics correlates better with VA(MLC) making this the visual performance test of choice.

摘要

目的

开发与视觉性能密切相关的单值波前像差指标。本研究的目的是探讨明视高对比度视力(VA)是否是合适的视觉性能参考指标,以及中视和/或低对比度测试是否具有任何优势。

方法

来自德克萨斯白内障光学研究的受试者(N = 148)年龄在21.6至83.8岁之间,涵盖从透明晶状体到致密核性白内障的情况。在四种条件下测量视力:明视高(VA(PHC))和低(VA(PLC))对比度、中视高(VA(MHC))和低(VA(MLC))对比度(明视 = 280 cd/m²,中视 = 0.75 cd/m²)。对变量进行正态性检验(偏度和峰度在 -2.00 < 偏度和峰度 < 2.00 范围内),并在需要时进行转换。使用线性回归和Bland-Altman 95%一致性界限(±1.96 SD)来检查VA变量之间以及VA与波前像差指标之间的关系。

结果

两种明视测量指标VA(PHC)(偏度 = 2.57,峰度 = 12.2)和VA(PLC)(1.67,5.41)分布不佳,但两种中视测量指标VA(MHC)(0.88,1.67)和VA(MLC)(0.29,-0.18)呈正态分布。(转换后的)VA变量之间存在强相关性(R:0.53至0.84)。然而,一致性界限范围为0.30至0.42 logMAR,而复测数据表明范围为0.15。对于30个波前指标,所有四个指标都用于逐步多元线性回归:20个仅包括VA(MLC),两个包括VA(PLC),两个包括VA(MHC),六个包括VA(MLC)和VA(MHC);R²平均为25%。

结论

尽管相关性很强,但低对比度和/或中视VA测试提供了不同的信息。波像差指标与VA(MLC)的相关性更好,使其成为首选的视觉性能测试。