Kuroki Hiroshi, Nakagawa Yasuaki, Mori Koji, Ohba Mao, Suzuki Takashi, Mizuno Yasuyuki, Ando Keiji, Takenaka Makoto, Ikeuchi Ken, Nakamura Takashi
Department of Orthopaedic Surgery, School of Health Sciences, Faculty of Medicine, Kyoto University, Kyoto, Japan.
Arthritis Res Ther. 2004;6(6):R492-504. doi: 10.1186/ar1219. Epub 2004 Sep 14.
We investigated quantitative changes over time in ultrasound signal intensity (an index of stiffness), signal duration (an index of surface irregularity), and interval between signals (an index of thickness) of plug cartilage in an animal model of autologous osteochondral grafting. A full-thickness osteochondral plug was surgically removed and replaced in male Japanese white rabbits (n = 22). Specimens obtained at day 0 and weeks 2, 4, 8, 12 and 24 postoperatively were assessed using an ultrasound system and by macroscopic and histological evaluation (modified Mankin's score). Histology revealed that the plug sank until 2 weeks postoperatively, and that newly formed cartilage-like tissue covered the plug, but at 24 weeks the tissue detached. The plug itself survived well throughout the period of observation. Although the signal intensity at the plug site was same as that in the sham operated contralateral knee at day 0, from 2 to 24 weeks postoperatively it was less than that in the sham knee. At 8 weeks, this difference was significant (P < 0.05). Modified Mankin's score revealed early degenerative changes at the site, but macroscopic examination did not. Signal intensity correlated significantly with score (both at day 0 and at the five postoperative time points [P < 0.05, r = -0.91] and as a whole [P < 0.05, r = -0.36]). Signal intensity also significantly correlated with the individual subscores for 'cartilage structure' (P < 0.05, r = -0.32) and 'cartilage cells' (P < 0.05, r = -0.30) from the modified Mankin's score, but not significantly with subscores for 'staining' and 'tidemark'. Signal duration correlated significantly with total score (as a whole [P < 0.05, r = 0.34]), but not significantly with the score for cartilage structure (P = 0.0557, r = 0.29). The interval between signals reflected well the actual thickness of the plug site. The significant relationships between ultrasound signal intensity and scores suggest that early degenerative changes in plug cartilage and cartilage-like tissue, especially in the superficial layer, are detectable by high-frequency ultrasound assessment.
我们在自体骨软骨移植动物模型中,研究了移植软骨的超声信号强度(硬度指标)、信号持续时间(表面不规则度指标)和信号间隔(厚度指标)随时间的定量变化。通过手术切除雄性日本白兔(n = 22)的全层骨软骨栓并进行置换。术后第0天、2周、4周、8周、12周和24周获取的标本,使用超声系统以及宏观和组织学评估(改良曼金评分)进行分析。组织学显示,移植栓在术后2周时下沉,新形成的软骨样组织覆盖移植栓,但在24周时组织分离。在整个观察期内,移植栓本身存活良好。虽然移植栓部位的信号强度在术后第0天时与假手术对侧膝关节相同,但在术后2至24周时低于假手术膝关节。在8周时,这种差异具有统计学意义(P < 0.05)。改良曼金评分显示该部位早期有退变改变,但宏观检查未发现。信号强度与评分显著相关(术后第0天以及五个术后时间点均如此[P < 0.05,r = -0.91],总体上也是如此[P < 0.05,r = -0.36])。信号强度还与改良曼金评分中的“软骨结构”(P < 0.05,r = -0.32)和“软骨细胞”(P < 0.05,r = -0.30)单项评分显著相关,但与“染色”和“潮线”单项评分无显著相关性。信号持续时间与总分显著相关(总体上[P < 0.05,r = 0.34]),但与软骨结构评分无显著相关性(P = 0.0557,r = 0.29)。信号间隔很好地反映了移植栓部位的实际厚度。超声信号强度与评分之间的显著关系表明,通过高频超声评估可检测到移植软骨和软骨样组织的早期退变改变,尤其是表层的改变。