Suppr超能文献

以800米跑速度进行力竭性跑步机跑步时的摄氧量反应:逐次呼吸分析

The VO2 response for an exhaustive treadmill run at 800-m pace: a breath-by-breath analysis.

作者信息

Draper S B, Wood D M

机构信息

School of Sport and Leisure, University of Gloucestershire, Oxstalls Campus, Oxstalls Lane, Gloucester, GL2 9HW, UK.

出版信息

Eur J Appl Physiol. 2005 Jan;93(4):381-9. doi: 10.1007/s00421-004-1278-z. Epub 2004 Nov 23.

Abstract

Recent research in which data were averaged over 10 or 30 s suggests that the VO(2) response of aerobically fit individuals plateaus below VO(2 max) in an exhaustive square-wave run lasting approximately 2 min. To investigate this phenomenon we examined the breath-by-breath VO(2) response of trained runners to an exhaustive treadmill run at 800 m pace. Eight male competitive runners completed two treadmill tests on separate days: a ramp test to exhaustion and an exhaustive square-wave run at 800-m pace. For the ramp test, the breath-by-breath data were smoothed with a 15-s moving average and the highest of the smoothed values was taken as VO(2 peak) [mean (SD): 68.9 (5.6) ml kg(-1) min(-1)]. For the square-wave, the breath-by-breath data were interpolated to give one value per second and modelled using a monoexponential function. Following a delay of 11.2 (1.5) s, VO(2) increased quickly [phase-2 time constant of 10.7 (2.7) s] towards an asymptote that represented just 85 (6)% of VO(2 peak) from the ramp test. Expressed in ml kg(-1) min(-1), this asymptote was independent of VO(2 peak) (r=0.04, P=0.94). However, as a percentage of VO(2 peak) it was negatively correlated with VO(2 peak) itself (r=-0.96, P<0.001). It is concluded that in an exhaustive square-wave treadmill run lasting approximately 2 min the VO(2) of aerobically fit runners increases quickly to plateau at a level that is lower than, but independent of, VO(2max).

摘要

近期一项对数据进行10秒或30秒平均处理的研究表明,在持续约2分钟的力竭性方波跑中,有氧适能个体的VO₂反应在低于VO₂max时趋于平稳。为了研究这一现象,我们检测了训练有素的跑步者在以800米配速进行力竭性跑步机跑步时逐次呼吸的VO₂反应。八名男性竞技跑步者在不同日期完成了两项跑步机测试:一项渐增负荷至力竭测试和一项以800米配速进行的力竭性方波跑。对于渐增负荷测试,逐次呼吸数据采用15秒移动平均值进行平滑处理,并将平滑后的值中的最高值作为VO₂峰值[均值(标准差):68.9(5.6)毫升·千克⁻¹·分钟⁻¹]。对于方波跑,逐次呼吸数据进行插值处理,以每秒给出一个值,并使用单指数函数进行建模。在延迟11.2(1.5)秒后,VO₂迅速增加[第二阶段时间常数为10.7(2.7)秒],直至达到一个渐近线,该渐近线仅代表渐增负荷测试中VO₂峰值的85(6)%。以毫升·千克⁻¹·分钟⁻¹表示,该渐近线与VO₂峰值无关(r = 0.04,P = 0.94)。然而,作为VO₂峰值的百分比,它与VO₂峰值本身呈负相关(r = -0.96,P < 0.001)。研究得出结论,在持续约2分钟的力竭性方波跑步机跑步中,有氧适能跑步者的VO₂迅速增加,然后在低于VO₂max但与之无关的水平趋于平稳。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验