Suppr超能文献

菠萝汁作为磁共振胰胆管造影术中的阴性口服对比剂:初步评估

Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: a preliminary evaluation.

作者信息

Riordan R D, Khonsari M, Jeffries J, Maskell G F, Cook P G

机构信息

Department of Radiology, Royal Cornwall Hospital, Truro, Cornwall TR1 3LJ, UK.

出版信息

Br J Radiol. 2004 Dec;77(924):991-9. doi: 10.1259/bjr/36674326.

Abstract

The quality of magnetic resonance cholangiopancreatography (MRCP) images is frequently degraded by high signal from the gastrointestinal tract. The aim of this study is to evaluate pineapple juice (PJ) as an oral negative contrast agent in MRCP. Preliminary in vitro evaluation demonstrated that PJ shortened T(2) relaxation time and hence decreased T(2) signal intensity on a standard MRCP sequence to a similar degree to a commercially available negative contrast agent (ferumoxsil). Electrothermal atomic absorption spectrometry assay demonstrated a high manganese concentration in PJ of 2.76 mg dl(-1), which is likely to be responsible for its T(2) imaging properties. MRCP was subsequently performed in 10 healthy volunteers, before and at 15 min and 30 min following ingestion of 400 ml of PJ. Images were assessed blindly by two Consultant Radiologists using a standard grading technique based on contrast effect (degree of suppression of bowel signal), and image effect (diagnostic quality). There were statistically significant improvements in contrast and image effect between pre and post PJ images. There was particularly significant improvement in visualization of the pancreatic duct, but no significant difference between 15 min and 30 min post PJ images. Visualization of the ampulla, common bile duct, common hepatic and central intrahepatic ducts were also significantly improved at 15 min following PJ. Our results demonstrate that PJ, may be used as an alternative to commercially available negative oral contrast agent in MRCP.

摘要

磁共振胰胆管造影(MRCP)图像的质量常常因胃肠道的高信号而降低。本研究的目的是评估菠萝汁(PJ)作为MRCP口服阴性对比剂的效果。初步体外评估表明,PJ缩短了T(2)弛豫时间,因此在标准MRCP序列上降低了T(2)信号强度,其程度与市售阴性对比剂(ferumoxsil)相似。电热原子吸收光谱法测定显示,PJ中的锰浓度很高,为2.76 mg dl(-1),这可能是其T(2)成像特性的原因。随后,对10名健康志愿者在摄入400 ml PJ之前、之后15分钟和30分钟进行了MRCP检查。两名放射科顾问医生采用基于对比效果(肠道信号抑制程度)和图像效果(诊断质量)的标准分级技术对图像进行了盲法评估。PJ前后图像之间的对比和图像效果有统计学意义的改善。胰管的可视化有特别显著的改善,但PJ后15分钟和30分钟的图像之间没有显著差异。PJ后15分钟时,壶腹、胆总管、肝总管和肝内中央胆管的可视化也有显著改善。我们的结果表明,在MRCP中,PJ可作为市售口服阴性对比剂的替代品。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验