Kinnard P, Asselin C
Division of Orthopedic Surgery, Centre Hospitalier de l'Université Laval, Ste-Foy, Que.
Can J Surg. 1992 Apr;35(2):192-3.
The authors reviewed, radiologically, the postoperative position of tibial component in 51 knee arthroplasties performed between 1987 and 1989 with Cartier's extramedullary tibial guide. The results compared favourably with those of other studies. A variation of 1.9 degrees on anteroposterior roentgenograms and 2.4 degrees on lateral roentgenograms was obtained by five orthopedic surgeons, suggesting that, for knee arthroplasties, the guide of Cartier is a useful tool and produces reliable results.
作者对1987年至1989年间使用卡地亚髓外胫骨导向器进行的51例膝关节置换术中胫骨组件的术后位置进行了影像学回顾。结果与其他研究相比很有利。五位骨科医生在前后位X线片上测得的偏差为1.9度,在侧位X线片上测得的偏差为2.4度,这表明,对于膝关节置换术来说,卡地亚导向器是一种有用的工具,并且能产生可靠的结果。