Suppr超能文献

足部矫形器对后足和胫骨关节耦合模式及变异性的影响。

Effect of foot orthotics on rearfoot and tibia joint coupling patterns and variability.

作者信息

Ferber Reed, Davis Irene McClay, Williams Dorsey S

机构信息

Human Performance Laboratory, Faculty of Kinesiology, 2500 University Drive NW, University of Calgary, Calgary, Alta., Canada T2N 1N4.

出版信息

J Biomech. 2005 Mar;38(3):477-83. doi: 10.1016/j.jbiomech.2004.04.019.

Abstract

The purpose of this study was to compare joint coupling patterns and variability of the rearfoot and tibia during running in subjects who were treated with two types of orthotic devices to that of controls. Eleven subjects with various lower extremity injuries were treated unsuccessfully with a standard orthotic, and then successfully with an inverted orthotic. Three-dimensional kinematic data were collected while subjects ran without orthoses and then in standard and inverted orthoses. Eleven healthy subjects ran without orthoses for comparison. The rearfoot inversion/eversion and tibial internal/external rotation joint coupling pattern and variability relationship was assessed using a vector coding technique. It was hypothesized that when the treated runners ran without orthotic devices, they would exhibit lower joint coupling angles and lower joint coupling variability compared to the controls. In addition, it was hypothesized that there would be no difference in the coupling angle or coupling variability between the standard and no orthotic conditions of the treated runners. Finally, it was hypothesized that coupling angle would decrease and variability would increase in the inverted versus the standard and non-orthotic conditions. No significant differences in joint coupling pattern or variability were observed between the treated and control subjects. In addition, no significant differences were noted between the orthotic conditions in the treated group. These results suggest that foot orthotic devices do not produce significant changes in rearfoot-tibial coupling. Therefore, the relief experienced with the inverted orthotic is likely due to factors other than alterations in this coupling.

摘要

本研究的目的是比较使用两种矫形器治疗的受试者在跑步过程中后足和胫骨的关节耦合模式及变异性与对照组的差异。11名患有各种下肢损伤的受试者使用标准矫形器治疗失败,随后使用内翻矫形器治疗成功。在受试者不使用矫形器跑步时,以及随后使用标准和内翻矫形器跑步时收集三维运动学数据。11名健康受试者不使用矫形器跑步作为对照。使用矢量编码技术评估后足内翻/外翻和胫骨内/外旋转关节耦合模式及变异性关系。研究假设,与对照组相比,接受治疗的跑步者在不使用矫形器跑步时,其关节耦合角度和关节耦合变异性会更低。此外,研究假设接受治疗的跑步者在标准矫形器和不使用矫形器的情况下,耦合角度或耦合变异性没有差异。最后,研究假设与标准和不使用矫形器的情况相比,内翻矫形器情况下耦合角度会减小,变异性会增加。在接受治疗的受试者和对照组之间未观察到关节耦合模式或变异性的显著差异。此外,在接受治疗的组中,矫形器情况之间也未发现显著差异。这些结果表明,足部矫形器不会在后足-胫骨耦合方面产生显著变化。因此,使用内翻矫形器所体验到的缓解可能是由于这种耦合改变之外的其他因素。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验