肱骨轴向旋转中的软组织伪影评估

Soft tissue artefact assessment in humeral axial rotation.

作者信息

Cutti Andrea Giovanni, Paolini Gabriele, Troncossi Marco, Cappello Angelo, Davalli Angelo

机构信息

DEIS, Department of Electronics, Computer Science and Systems, University of Bologna, Viale Risorgimento 2, I-40136 Bologna, Italy.

出版信息

Gait Posture. 2005 Apr;21(3):341-9. doi: 10.1016/j.gaitpost.2004.04.001.

Abstract

The accuracy of upper-limb kinematic data acquired from optoelectronic systems with retro-reflective markers is poor, mainly due to soft tissue artefact (STA). For the upper-arm, humeral internal/external rotation (HIER) is the movement most affected by STA, which is measured as a percentile fraction (K) of the effective humeral axial rotation performed. The aim of this work was to quantify STA during HIERs, with independently varying attitude of the humerus and elbow flexion, and to test the possibility of estimating its mean value over the tested upper-limb orientations using one simple trial. Six able-bodied subjects performed a series of HIERs in combination with elbow flexion for different humeral planes and degrees of elevation. During the trials the instantaneous attitudes of two humeral anatomical frames were compared, one being affected by the STA to be measured, and the other assumed as the gold standard. K was found to range from 20% to 48% of the effective humeral axial rotation performed, depending on the subject, humeral attitude and elbow flexion. These last two factors comparably affect STA and resulted in mean K coefficients of variation among the subjects of about 9% and 7%, respectively. Common patterns of K with elbow flexion and humerus elevation are discussed. The data also show that the mean of K of a subject is very close to the value assessed in a specific upper-limb configuration consistent among the subjects. This result from this study could be used to build up a time-saving STA compensation procedure suitable for clinical applications.

摘要

从带有反光标记的光电系统获取的上肢运动学数据准确性较差,主要原因是软组织伪影(STA)。对于上臂而言,肱骨内/外旋转(HIER)是受STA影响最大的运动,其测量方式为有效肱骨轴向旋转量的百分分数(K)。本研究的目的是在HIER过程中,独立改变肱骨姿态和肘关节屈曲程度,对STA进行量化,并测试通过一次简单试验估计在测试的上肢方位上其平均值的可能性。六名身体健全的受试者针对不同的肱骨平面和抬高程度,结合肘关节屈曲进行了一系列HIER。在试验过程中,比较了两个肱骨解剖坐标系的瞬时姿态,一个受待测量的STA影响,另一个作为金标准。结果发现,K值占有效肱骨轴向旋转量的20%至48%,具体取决于受试者、肱骨姿态和肘关节屈曲程度。后两个因素对STA的影响相当,导致受试者之间K系数的平均变异分别约为9%和7%。文中讨论了K随肘关节屈曲和肱骨抬高的常见模式。数据还表明,受试者的K平均值非常接近在受试者之间一致的特定上肢配置中评估的值。本研究结果可用于建立一种适用于临床应用的省时STA补偿程序。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验