Quantifying errors in spectral estimates of HRV due to beat replacement and resampling.

作者信息

Clifford Gari D, Tarassenko Lionel

机构信息

Department of Engineering Science, University of Oxford, Oxford OX1 3PJ, UK.

出版信息

IEEE Trans Biomed Eng. 2005 Apr;52(4):630-8. doi: 10.1109/TBME.2005.844028.


DOI:10.1109/TBME.2005.844028
PMID:15825865
Abstract

Spectral estimates of heart rate variability (HRV) often involve the use of techniques such as the fast Fourier transform (FFT), which require an evenly sampled time series. HRV is calculated from the variations in the beat-to-beat (RR) interval timing of the cardiac cycle which are inherently irregularly spaced in time. In order to produce an evenly sampled time series prior to FFT-based spectral estimation, linear or cubic spline resampling is usually employed. In this paper, by using a realistic artificial RR interval generator, interpolation and resampling is shown to result in consistent over-estimations of the power spectral density (PSD) compared with the theoretical solution. The Lomb-Scargle (LS) periodogram, a more appropriate spectral estimation technique for unevenly sampled time series that uses only the original data, is shown to provide a superior PSD estimate. Ectopy removal or replacement is shown to be essential regardless of the spectral estimation technique. Resampling and phantom beat replacement is shown to decrease the accuracy of PSD estimation, even at low levels of ectopy or artefact. A linear relationship between the frequency of ectopy/artefact and the error (mean and variance) of the PSD estimate is demonstrated. Comparisons of PSD estimation techniques performed on real RR interval data during minimally active segments (sleep) demonstrate that the LS periodogram provides a less noisy spectral estimate of HRV.

摘要

相似文献

[1]
Quantifying errors in spectral estimates of HRV due to beat replacement and resampling.

IEEE Trans Biomed Eng. 2005-4

[2]
Sampling frequency of the RR interval time series for spectral analysis of heart rate variability.

J Med Eng Technol. 2004

[3]
Power spectral density of unevenly sampled data by least-square analysis: performance and application to heart rate signals.

IEEE Trans Biomed Eng. 1998-6

[4]
An improved windowing technique for heart rate variability power spectrum estimation.

J Med Eng Technol. 2005

[5]
Hilbert-Huang transform for analysis of heart rate variability in cardiac health.

IEEE/ACM Trans Comput Biol Bioinform. 2011

[6]
Unique very low-frequency heart rate variability during deep sleep in humans.

IEEE Trans Biomed Eng. 2006-1

[7]
Time domain parameters can be estimated with less statistical error than frequency domain parameters in the analysis of heart rate variability.

J Electrocardiol. 2008

[8]
Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal.

IEEE Trans Biomed Eng. 2003-3

[9]
QT variability and HRV interactions in ECG: quantification and reliability.

IEEE Trans Biomed Eng. 2006-7

[10]
Kullback-Leibler clustering of continuous wavelet transform measures of heart rate variability.

Biomed Sci Instrum. 2004

引用本文的文献

[1]
Wearable multimodal sensing for quantifying the cardiovascular autonomic effects of levodopa in parkinsonism.

Front Netw Physiol. 2025-4-24

[2]
Establishing normative values for short-term heart rate variability indices in healthy infants in the emergency department.

Ann Transl Med. 2025-2-28

[3]
Characterization of cardiac autonomic dysfunction in acute Schizophrenia: a cluster analysis of heart rate variability parameters.

Schizophrenia (Heidelb). 2025-3-8

[4]
Robust and time-resolved estimation of cardiac sympathetic and parasympathetic indices.

R Soc Open Sci. 2025-1-15

[5]
Robust and time-resolved estimation of cardiac sympathetic and parasympathetic indices.

bioRxiv. 2024-9-24

[6]
Publication guidelines for human heart rate and heart rate variability studies in psychophysiology-Part 1: Physiological underpinnings and foundations of measurement.

Psychophysiology. 2024-9

[7]
Construction of a comprehensive fetal monitoring database for the study of perinatal hypoxic ischemic encephalopathy.

MethodsX. 2024-3-12

[8]
An extensive quantitative analysis of the effects of errors in beat-to-beat intervals on all commonly used HRV parameters.

Sci Rep. 2024-1-30

[9]
Wearable Sensors as a Preoperative Assessment Tool: A Review.

Sensors (Basel). 2024-1-12

[10]
Neurophysiological mental fatigue assessment for developing user-centered Artificial Intelligence as a solution for autonomous driving.

Front Neurorobot. 2023-11-30

文献AI研究员