Cazabon L, Casillas J M, Ader P, Grumler B, Lothe M, Dulieu V
Inserm ERITm 0207, pôle de rééducation-réadaptation, CHU de Dijon, 23, rue Gaffarel, 21079 Dijon cedex, France.
Ann Readapt Med Phys. 2005 Apr;48(3):118-25. doi: 10.1016/j.annrmp.2004.10.006.
To assess by a specific questionnaire the functional outcome of patients with below-the-knee amputation after early prosthetic fitting by the ICEROSS silicone liner, which had demonstrated improvement of stump healing and length of hospital stay.
In this retrospective study, walking ability was assessed by a specific score resulting from answers on a questionnaire. The outcome variables were walking inside and outside, transfer from sitting, climbing stairs, and use of walking aids. Following amputation, the ICEROSS system was used for compression therapy, then for temporary prosthesis. The questionnaire was administered at the fitting stabilized state.
Twenty-nine of 51 patients who underwent trans-tibial amputation were included: 5 women (mean age 72.8+/-4.1 years) and 24 men (mean age: 69+/-7.4 years). The mean total score was 14.5/20 (good functional outcome) for the 22 unilateral amputees and 7.2/20 (intermediate result) for the seven bilateral amputees. Previous studies concerning functional outcome with other contact casts (without a silicon liner with a bolt) had shown similar results.
Despite its beneficial initial effect, early fitting by the ICEROSS system did not improve walking ability at the steady functional state, which is more linked to advanced age and comorbidities.
通过一份特定问卷评估采用ICEROSS硅胶内衬进行早期假肢装配的膝下截肢患者的功能结局,该内衬已证明可改善残端愈合情况及缩短住院时间。
在这项回顾性研究中,行走能力通过问卷答案得出的特定评分进行评估。结局变量包括室内外行走、从坐姿转移、爬楼梯以及使用助行器的情况。截肢后,ICEROSS系统用于压迫治疗,然后用于临时假肢。问卷在装配稳定状态时进行发放。
纳入了51例行胫骨截肢术患者中的29例:5名女性(平均年龄72.8±4.1岁)和24名男性(平均年龄:69±7.4岁)。22名单侧截肢患者的平均总分是14.5/20(良好的功能结局),7名双侧截肢患者的平均总分是7.2/20(中等结果)。此前关于其他接触式石膏(无带螺栓的硅胶内衬)功能结局的研究显示了类似结果。
尽管ICEROSS系统初期有有益效果,但在稳定功能状态下,早期装配并未改善行走能力,这与高龄和合并症关系更大。