胰岛素检测的分析前要求有限。

Limited preanalytical requirements for insulin measurement.

作者信息

Vogeser Michael, Parhofer Klaus G

机构信息

Institute of Clinical Chemistry, Hospital of the University of Munich, Marchioninistrasse 15, D-81377 Munich, Germany.

出版信息

Clin Biochem. 2005 Jun;38(6):572-5. doi: 10.1016/j.clinbiochem.2005.03.003.

Abstract

OBJECTIVES

To evaluate the stability of insulin in serum and plasma under conditions relevant for the transport of samples from outpatient clinics to a centralized laboratory.

DESIGN AND METHODS

Venous blood samples were taken from 15 volunteers and processed either immediately or after storage at room temperature for 24 h. The effect of EDTA or sodium fluoride on insulin results was investigated.

RESULTS

Insulin was found to be stable in EDTA-containing tubes at room temperature for at least 24 h, whereas significantly lower concentrations were found if samples without additives or potassium fluoride as an additive were used.

CONCLUSIONS

If shipment of patients' samples for insulin measurement from an outpatient clinic to a centralized laboratory can be performed within 24 h, centrifugation and freezing of plasma is not required. These findings facilitate a widespread application of insulin measurements to characterize and follow-up individual insulin sensitivity.

摘要

目的

评估在与门诊样本运输至集中实验室相关的条件下,胰岛素在血清和血浆中的稳定性。

设计与方法

采集15名志愿者的静脉血样本,立即处理或在室温下储存24小时后处理。研究了乙二胺四乙酸(EDTA)或氟化钠对胰岛素检测结果的影响。

结果

发现胰岛素在含EDTA的试管中于室温下至少24小时内稳定,而如果使用无添加剂或添加氟化钾的样本,则胰岛素浓度显著降低。

结论

如果能在24小时内将患者用于胰岛素检测的样本从门诊运输至集中实验室,则无需对血浆进行离心和冷冻。这些发现有助于胰岛素检测在个体胰岛素敏感性特征描述和随访中的广泛应用。