A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.

作者信息

Stange L, Wussow C

出版信息

Int J Gynaecol Obstet. 1976;14(4):357-63. doi: 10.1002/j.1879-3479.1976.tb00627.x.

DOI:10.1002/j.1879-3479.1976.tb00627.x
PMID:15896
Abstract

A transcutaneous PO2 electrode has been designed and constructed for the continuous measurement of fetal oxygen tension during labor and delivery. The electrode, tested in vitro, has a low oxygen consumption, a short response time, 10 sec, and a sufficient stability, 5% over 3 hr. The in vivo performance of the electrode, tested in neonates, shows a good correlation between transcutaneous PO2 and PO2 measured in samples of arterial blood. The continous registration of fetal tcPO2 during labor and delivery is exemplified.

摘要

相似文献

1
A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.
Int J Gynaecol Obstet. 1976;14(4):357-63. doi: 10.1002/j.1879-3479.1976.tb00627.x.
2
Continuous measurement of transcutaneous fetal oxygen tension during labour.分娩期间经皮胎儿氧分压的连续测量。
Br J Obstet Gynaecol. 1979 Dec;86(12):954-8. doi: 10.1111/j.1471-0528.1979.tb11243.x.
3
Monitoring of transcutaneous PO2 in the fetus and mother during normal labor.
J Perinat Med. 1977;5(6):252-9. doi: 10.1515/jpme.1977.5.6.252.
4
Measurement of fetal transcutaneous oxygen tension--problems and potential.
Br J Obstet Gynaecol. 1979 Dec;86(12):948-53. doi: 10.1111/j.1471-0528.1979.tb11242.x.
5
Simultaneous measurement of fetal tissue pH and transcutaneous pO2 during labor.
Eur J Obstet Gynecol Reprod Biol. 1984 May;17(2-3):69-76. doi: 10.1016/0028-2243(84)90131-x.
6
Preliminary data on the clinical use of a self-constructed transcutaneous PO2 electrode during labor.自制经皮氧分压电极在分娩过程中临床应用的初步数据。
Birth Defects Orig Artic Ser. 1979;15(4):245-8.
7
Subcutaneous oxygen tension in the fetal scalp during labour continuous monitoring with a needle electrode.
Br J Obstet Gynaecol. 1981 May;88(5):517-24. doi: 10.1111/j.1471-0528.1981.tb01026.x.
8
Reliability of transcutaneous measurement of oxygen and carbon dioxide partial pressure with a combined Po2-Pco2 electrochemical sensor in the fetus during labor.
J Perinat Med. 1985;13(3):127-33. doi: 10.1515/jpme.1985.13.3.127.
9
Transcutaneous oxygen measurement to evaluate drug effects.经皮氧测量以评估药物效果。
Clin Perinatol. 1979 Mar;6(1):109-21.
10
Measurement of transcutaneous pCO2 and pO2 in the fetus during labor.分娩期间胎儿经皮二氧化碳分压和氧分压的测量。
Arch Gynecol. 1985;236(3):145-51. doi: 10.1007/BF02133957.