• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Subcutaneous oxygen tension in the fetal scalp during labour continuous monitoring with a needle electrode.

作者信息

Aarnoudse J G, Huisjes H J, Oeseburg B, Zijlstra W G

出版信息

Br J Obstet Gynaecol. 1981 May;88(5):517-24. doi: 10.1111/j.1471-0528.1981.tb01026.x.

DOI:10.1111/j.1471-0528.1981.tb01026.x
PMID:7236555
Abstract

Continuous intrapartum PO2 recordings were made in 25 fetuses, using a needle electrode that measures PO2 in the subcutaneous (sc) tissue of the scalp or the breech. This small electrode is combined with a spiral ECG electrode and can be easily applied in early labour. One hour after application of the electrode in the early first stage, a mean fetal scPO2 of 29.4 +/- 7.5 mm Hg was found. In the course of labour, scPO2 gradually fell to a mean value of 22.2 +/- 5.6 mm Hg, recorded just before the onset of bearing down contractions, and stabilised in the second stage of labour. ScPO2 values of less than 20 mm Hg were not recorded for a longer period except in one case of severe fetal distress. The relation between scPO2 just before delivery and cord arterial PO2 revealed a coefficient of correlation of 0.85. In general, scPO2 appeared higher than tcPO2 as described in the literature. This is ascribed to the different technique of measurement: the needle electrode measures in the deeper layers of the scalp, whereas the tc electrode is supplied with oxygen form the more superficial capillaries, where blood flow is more liable to be affected by mechanical factors.

摘要

相似文献

1
Subcutaneous oxygen tension in the fetal scalp during labour continuous monitoring with a needle electrode.
Br J Obstet Gynaecol. 1981 May;88(5):517-24. doi: 10.1111/j.1471-0528.1981.tb01026.x.
2
Continuous measurement of transcutaneous fetal oxygen tension during labour.分娩期间经皮胎儿氧分压的连续测量。
Br J Obstet Gynaecol. 1979 Dec;86(12):954-8. doi: 10.1111/j.1471-0528.1979.tb11243.x.
3
Measurement of fetal transcutaneous oxygen tension--problems and potential.
Br J Obstet Gynaecol. 1979 Dec;86(12):948-53. doi: 10.1111/j.1471-0528.1979.tb11242.x.
4
Fetal subcutaneous scalp PO2 and abnormal heart rate during labor.分娩期间胎儿头皮下血氧分压及异常心率
Am J Obstet Gynecol. 1985 Nov 1;153(5):565-6. doi: 10.1016/0002-9378(85)90476-4.
5
Monitoring of transcutaneous PO2 in the fetus and mother during normal labor.
J Perinat Med. 1977;5(6):252-9. doi: 10.1515/jpme.1977.5.6.252.
6
Variability of fetal scalp blood flow during labour: continuous transcutaneous measurement by the laser Doppler technique.分娩期间胎儿头皮血流的变异性:激光多普勒技术连续经皮测量
Br J Obstet Gynaecol. 1984 Jun;91(6):524-31. doi: 10.1111/j.1471-0528.1984.tb04797.x.
7
The continuous measurement of tissue pH in the human fetus during labour using a new application technique.
Br J Obstet Gynaecol. 1980 Aug;87(8):666-8. doi: 10.1111/j.1471-0528.1980.tb04598.x.
8
Influence of variations in pH and PCO2 on scalp tissue oxygen tension and carotid arterial oxygen tension in the fetal lamb.pH值和二氧化碳分压变化对胎羊头皮组织氧张力和颈动脉血氧张力的影响。
Biol Neonate. 1981;40(5-6):252-63. doi: 10.1159/000241501.
9
A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.
Int J Gynaecol Obstet. 1976;14(4):357-63. doi: 10.1002/j.1879-3479.1976.tb00627.x.
10
A nonpenetrating fetal scalp electrode.一种非侵入性胎儿头皮电极。
Br J Obstet Gynaecol. 1993 Jul;100(7):649-52. doi: 10.1111/j.1471-0528.1993.tb14232.x.