分娩期间经皮胎儿氧分压的连续测量。

Continuous measurement of transcutaneous fetal oxygen tension during labour.

作者信息

Weber T, Secher N J

出版信息

Br J Obstet Gynaecol. 1979 Dec;86(12):954-8. doi: 10.1111/j.1471-0528.1979.tb11243.x.

DOI:10.1111/j.1471-0528.1979.tb11243.x
PMID:526453
Abstract

Transcutaneous scalp oxygen tension (tcPO2) was measured during labour in 40 fetuses, using a modified Clark electrode (Radiometer, Copenhagen). In 24 of the fetuses the recordings were of good quality during the second stage of labour. After delivery the acid-base status and oxygenation of the umbilical cord blood was measured. A correlation was found between the tcPO2 and umbilical artery oxygen saturation (r = 0.56, p less than 0.01) and umbilical artery PO2 (r = 0.56, p less than 0.01). Furuthermore, a positive correlation was found between the area beneath the recorded tcPO2 curve during the last 10 minutes and the umbilical artery pH (r = 0.50, p less than 0.05). The data suggest that continuous transcutaneous PO2 measurement may be of value in monitoring high risk patients during labour.

摘要

使用改良的克拉克电极(Radiometer,哥本哈根)对40例胎儿在分娩过程中进行经皮头皮氧分压(tcPO2)测量。其中24例胎儿在第二产程中的记录质量良好。分娩后测量脐血的酸碱状态和氧合情况。发现tcPO2与脐动脉氧饱和度(r = 0.56,p < 0.01)以及脐动脉PO2(r = 0.56,p < 0.01)之间存在相关性。此外,在最后10分钟记录的tcPO2曲线下面积与脐动脉pH之间存在正相关(r = 0.50,p <

相似文献

1
Continuous measurement of transcutaneous fetal oxygen tension during labour.分娩期间经皮胎儿氧分压的连续测量。
Br J Obstet Gynaecol. 1979 Dec;86(12):954-8. doi: 10.1111/j.1471-0528.1979.tb11243.x.
2
Measurement of fetal transcutaneous oxygen tension--problems and potential.
Br J Obstet Gynaecol. 1979 Dec;86(12):948-53. doi: 10.1111/j.1471-0528.1979.tb11242.x.
3
Reliability of transcutaneous measurement of oxygen and carbon dioxide partial pressure with a combined Po2-Pco2 electrochemical sensor in the fetus during labor.
J Perinat Med. 1985;13(3):127-33. doi: 10.1515/jpme.1985.13.3.127.
4
Subcutaneous oxygen tension in the fetal scalp during labour continuous monitoring with a needle electrode.
Br J Obstet Gynaecol. 1981 May;88(5):517-24. doi: 10.1111/j.1471-0528.1981.tb01026.x.
5
A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.
Int J Gynaecol Obstet. 1976;14(4):357-63. doi: 10.1002/j.1879-3479.1976.tb00627.x.
6
Simultaneous measurement of fetal tissue pH and transcutaneous pO2 during labor.
Eur J Obstet Gynecol Reprod Biol. 1984 May;17(2-3):69-76. doi: 10.1016/0028-2243(84)90131-x.
7
Non-invasive continuous fetal transcutaneous pO2 and pCO2 monitoring during labor.
J Perinat Med. 1989;17(6):399-410. doi: 10.1515/jpme.1989.17.6.399.
8
Measurement of transcutaneous pCO2 and pO2 in the fetus during labor.分娩期间胎儿经皮二氧化碳分压和氧分压的测量。
Arch Gynecol. 1985;236(3):145-51. doi: 10.1007/BF02133957.
9
The difference between fetal transcutaneous pO2 and arterial pO2 during labour.分娩期间胎儿经皮氧分压与动脉血氧分压的差异。
Gynecol Obstet Invest. 1980;11(5):249-64. doi: 10.1159/000299845.
10
Monitoring of transcutaneous PO2 in the fetus and mother during normal labor.
J Perinat Med. 1977;5(6):252-9. doi: 10.1515/jpme.1977.5.6.252.

引用本文的文献

1
Neonatal hyperoxia exposure disrupts axon-oligodendrocyte integrity in the subcortical white matter.新生儿高氧暴露会破坏皮质下白质中的轴突-少突胶质细胞完整性。
J Neurosci. 2013 May 22;33(21):8990-9002. doi: 10.1523/JNEUROSCI.5528-12.2013.