Suppr超能文献

与颈部肌肉疲劳的肌电图(EMG)和伯格量表评估的重复性及相关性相关的问题。

Issues in relation to the repeatability of and correlation between EMG and Borg scale assessments of neck muscle fatigue.

作者信息

Strimpakos Nikolaos, Georgios Gioftsos, Eleni Kapreli, Vasilios Kalapotharakos, Jacqueline Oldham

机构信息

Centre for Rehabilitation Science, Central Manchester and Manchester Children's Hospital's NHS Trust, University of Manchester, Oxford Road, Manchester M13 9WL, UK.

出版信息

J Electromyogr Kinesiol. 2005 Oct;15(5):452-65. doi: 10.1016/j.jelekin.2005.01.007. Epub 2005 Mar 2.

Abstract

INTRODUCTION

The repeatability of subjective and objective assessments of neck muscle fatigue is very important with regard to the clinical applicability of these methods.

METHOD

To establish between-days reliability, 33 healthy volunteers performed a 60% maximum voluntary isometric contraction test from a standing position in all neck movements. Cervical muscle fatigue was assessed on three separate occasions from the spectral (median frequency, MF) and amplitude (root mean square, RMS) analysis of the electromyogram (EMG) signal recorded from the cervical paraspinal group, splenius capitis, levator scapulae and sternocleidomastoid. Subjective assessment of fatigue was rated by employing the Borg scale. Intraclass correlation coefficient ICC((1,1)), standard error of measurement (SEM), smallest detectable difference (SDD) indices and Pearson's correlation co-efficient were calculated for the analysis of the results.

RESULTS

Normalised median frequency (MF) slope had low repeatability and large between-day error (ICC((1,1))=0.28-0.61; SEM=0.33-0.60%/s; SDD=132.7-703.2%) for the protagonist muscles of each movement. Initial median frequency (IMF) had moderate to good reliability and small error (ICC((1,1))=0.64-0.81; SEM=2.8-8.8Hz; SDD=19.9-38.5%). The RMS slope yielded also poor repeatability. The Borg assessment was more reliable than the EMG estimate though variability between sessions was still quite high (SDD=29.2-136.5%). No correlation was found between the EMG and Borg assessment of neck muscle fatigue (r=-0.01-0.39).

CONCLUSION

The protocol used for assessing neck muscle fatigue proved to be reliable only for the IMF but the clinical usefulness of this measure remains questionable. The lack of correlation between objective and subjective estimation of neck muscle fatigue was possibly a consequence of the poor measurement repeatability. Further research is needed to identify the factors responsible for these results on neck area.

摘要

引言

颈部肌肉疲劳的主观和客观评估的可重复性对于这些方法的临床适用性而言非常重要。

方法

为了确定日间可靠性,33名健康志愿者在所有颈部运动中从站立姿势进行60%最大自主等长收缩测试。在三个不同的时间点,通过对从颈旁肌群、头夹肌、肩胛提肌和胸锁乳突肌记录的肌电图(EMG)信号进行频谱分析(中位频率,MF)和幅度分析(均方根,RMS)来评估颈部肌肉疲劳。采用Borg量表对疲劳进行主观评估。计算组内相关系数ICC((1,1))、测量标准误差(SEM)、最小可检测差异(SDD)指数和皮尔逊相关系数以分析结果。

结果

每个运动的主动肌的标准化中位频率(MF)斜率具有低可重复性和较大的日间误差(ICC((1,1)) = 0.28 - 0.61;SEM = 0.33 - 0.60%/秒;SDD = 132.7 - 703.2%)。初始中位频率(IMF)具有中等至良好的可靠性和较小的误差(ICC((1,1)) = 0.64 - 0.81;SEM = 2.8 - 8.8赫兹;SDD = 19.9 - 38.5%)。RMS斜率的可重复性也很差。Borg评估比EMG估计更可靠,尽管各次测试之间的变异性仍然相当高(SDD = 29.2 - 136.5%)。在颈部肌肉疲劳的EMG和Borg评估之间未发现相关性(r = -0.01 - 0.39)。

结论

用于评估颈部肌肉疲劳的方案仅被证明对IMF可靠,但该测量方法的临床实用性仍然存疑。颈部肌肉疲劳的客观和主观估计之间缺乏相关性可能是测量可重复性差的结果。需要进一步研究以确定导致颈部区域出现这些结果的因素。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验