Suppr超能文献

基于小波变换和傅里叶变换的肌电图(即时)中位频率在等长背部伸展运动中评估背部和臀部肌肉疲劳时的重测信度。

Test-retest reliability of wavelet - and Fourier based EMG (instantaneous) median frequencies in the evaluation of back and hip muscle fatigue during isometric back extensions.

作者信息

Coorevits Pascal, Danneels Lieven, Cambier Dirk, Ramon Herman, Druyts Hans, Karlsson J Stefan, De Moor Georges, Vanderstraeten Guy

机构信息

RAMIT vzw, Department of Medical Informatics and Statistics, Ghent University Hospital, Building K3, 5th Floor, De Pintelaan 185, 9000 Ghent, Belgium.

出版信息

J Electromyogr Kinesiol. 2008 Oct;18(5):798-806. doi: 10.1016/j.jelekin.2007.01.007. Epub 2008 Apr 8.

Abstract

The present study aimed at assessing the test-retest reliability of wavelet - and Fourier derived (instantaneous) median frequencies of surface electromyographic (EMG) measurements of back and hip muscles during isometric back extensions. Twenty healthy subjects (10 males and 10 females) performed a modified Biering-Sørensen test on two separate days, with a 1-week interval between the two tests. Surface EMG measurements were bilaterally performed from the latissimus dorsi, the thoracic and lumbar parts of the longissimus thoracis, the thoracic and lumbar parts of the iliocostalis lumborum, the multifidus, the gluteus maximus and the biceps femoris. In addition, three-dimensional kinematic data were recorded of the subjects' lumbar vertebrae. The (instantaneous) median frequencies were calculated from the EMG signals using continuous wavelet (IMDF) - and short-time Fourier transforms (MDF). Linear regressions performed on the IMDF and MDF data as a function of time yielded slopes (IMDF(slope) and MDF(slope)) and intercepts (IMDF(init) and MDF(init)) of the regression lines. Test-retest reliability was assessed on the normalized slopes and intercept parameters by means of intraclass correlation coefficients (ICC) and standard errors of measurements expressed as percentages of the mean values (% SEM). The results of IMDF(slope) and MDF(slope) parameters indicated ICCs for back and hip muscles between .443 and .727 for IMDF(slope), values between .273 and .734 for MDF(slope), % SEM between 7.6% and 58.9% for IMDF(slope) and % SEM between 8.2% and 25.3% for MDF(slope), respectively. The ICCs for IMDF(init) and MDF(init) parameters varied between .376 and .907 for IMDF(init) and between .383 and .883 for MDF(init), and % SEM ranged from 2.7% to 6.3% for IMDF(init) and from 2.6% to 4.7% for MDF(init), respectively. These results indicate that both wavelet - and Fourier based (instantaneous) median frequency parameters generally are reliable in the analysis of back and hip muscle fatigue during a modified Biering-Sørensen test.

摘要

本研究旨在评估在等长伸背过程中,通过小波变换和傅里叶变换得出的背部和臀部肌肉表面肌电图(EMG)测量的(瞬时)中位频率的重测信度。20名健康受试者(10名男性和10名女性)在两个不同日期进行了改良的比林-索伦森测试,两次测试间隔1周。双侧从背阔肌、胸腰段竖脊肌、胸腰段腰髂肋肌、多裂肌、臀大肌和股二头肌进行表面肌电图测量。此外,记录了受试者腰椎的三维运动学数据。使用连续小波变换(IMDF)和短时傅里叶变换(MDF)从肌电图信号中计算(瞬时)中位频率。对IMDF和MDF数据随时间进行线性回归,得出回归线的斜率(IMDF(斜率)和MDF(斜率))和截距(IMDF(初始值)和MDF(初始值))。通过组内相关系数(ICC)和以平均值百分比表示的测量标准误差(%SEM)评估重测信度的标准化斜率和截距参数。IMDF(斜率)和MDF(斜率)参数的结果表明,背部和臀部肌肉的IMDF(斜率)的ICC在0.443至0.727之间,MDF(斜率)的值在0.273至0.734之间,IMDF(斜率)的%SEM在7.6%至58.9%之间,MDF(斜率)的%SEM分别在8.2%至25.3%之间。IMDF(初始值)和MDF(初始值)参数的ICC在IMDF(初始值)为0.376至0.907之间,MDF(初始值)为0.383至0.883之间,IMDF(初始值)的%SEM范围为2.7%至6.3%,MDF(初始值)的%SEM范围为2.6%至4.7%。这些结果表明,在改良的比林-索伦森测试中,基于小波变换和傅里叶变换的(瞬时)中位频率参数在分析背部和臀部肌肉疲劳方面通常是可靠的。