Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging.

作者信息

Notomi Yuichi, Lysyansky Peter, Setser Randolph M, Shiota Takahiro, Popović Zoran B, Martin-Miklovic Maureen G, Weaver Joan A, Oryszak Stephanie J, Greenberg Neil L, White Richard D, Thomas James D

机构信息

Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA.

出版信息

J Am Coll Cardiol. 2005 Jun 21;45(12):2034-41. doi: 10.1016/j.jacc.2005.02.082.

Abstract

OBJECTIVES

We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach).

BACKGROUND

Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence.

METHODS

We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images.

RESULTS

Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias.

CONCLUSIONS

The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.

摘要

目的

我们试图检验一种用于测量左心室扭转(LVtor)的新型超声斑点追踪成像(STI)方法的准确性/一致性,并与标记磁共振成像(MRI)(一种类似于STI的时域方法)和多普勒组织成像(DTI)(一种基于速度的方法)进行比较。

背景

螺旋状排列的肌纤维产生的左心室扭转是心脏功能的一个关键参数,但难以测量。超声STI因其角度独立性,可能适用于测量角向运动。

方法

我们采集了15例患者的左心室(LV)基底和心尖短轴图像,通过STI估计LVtor,并将其与标记MRI和DTI进行比较。左心室扭转定义为基底和心尖平面LV旋转的净差值。对于STI分析,我们使用了高帧频(104±12帧/秒)的二次谐波二维图像。

结果

15例患者中有13例的数据可用于STI分析,STI估计的LVtor轮廓与标记MRI估计的轮廓高度相关(y = 0.95x + 0.19,r = 0.93,p < 0.0001,通过重复测量回归模型分析)。STI扭转速度轮廓与DTI方法的轮廓也具有良好的相关性(y = 0.79x + 2.4,r = 0.76,p < 0.0001,通过重复测量回归模型),偏差可接受。

结论

STI对LVtor的估计与标记MRI分析(源自组织位移的数据)一致,并且与DTI分析(源自组织速度的数据)也显示出良好的一致性。超声STI是一种有前景的评估LV扭转变形的新方法,可能使临床和研究心脏病学中的评估更加可行。