Gleissner M, Lachenmayr B J
Augenklinik, Universität München.
Ophthalmologe. 1992 Apr;89(2):162-5.
The influence of defocus, artificial media opacities and pupil size on perimetric thresholds in automated light sense and flicker perimetry was investigated in 20 eyes of 20 normal subjects. Thresholds were determined at 13 locations in the central visual field. Blurring the retinal image by a small defocus or by slight artificial media opacities causes a measurable reduction in light-difference sensitivity. Flicker fusion frequency, however, is much more resistant to degradation of the retinal image. Artificial pupil size has a similar effect on both light-difference sensitivity and flicker fusion frequency. The present study shows that perimetric methods using temporal threshold criteria should be more suitable for the detection of neuronal damage in the presence of factors disturbing the quality of the retinal image than methods using static criteria.
在20名正常受试者的20只眼中,研究了散焦、人工介质混浊和瞳孔大小对自动光感视野计和闪烁视野计周边阈值的影响。在中央视野的13个位置测定阈值。通过小散焦或轻微的人工介质混浊使视网膜图像模糊会导致光差异敏感度出现可测量的降低。然而,闪烁融合频率对视网膜图像退化的抵抗力要强得多。人工瞳孔大小对光差异敏感度和闪烁融合频率有类似影响。本研究表明,在存在干扰视网膜图像质量因素的情况下,使用时间阈值标准的视野计方法比使用静态标准的方法更适合检测神经元损伤。