Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.

摘要

非接触式电导检测已成功应用于毛细管电泳(CE)中碱性药物和氨基酸的对映体分离。无需像间接光学检测方案那样对化合物进行衍生化或添加可视化剂。使用了不带电荷的手性选择剂,对于亲脂性更强的碱性药物使用羟丙基化环糊精(CD),对于氨基酸使用18-冠-6-四羧酸(18C6H4)。使用了基于乳酸或柠檬酸的酸性缓冲溶液。以伪麻黄碱作为碱性药物的示例,其检测限确定为0.3微摩尔,氨基酸的检测限范围为2.5至20微摩尔。