Bach David S, Kon Neal D, Dumesnil Jean G, Sintek Colleen F, Doty Donald B
Division of Cardiology, Department of Medicine, University of Michigan, Ann Arbor, Michigan, USA.
Ann Thorac Surg. 2005 Aug;80(2):480-6; discussion 486-7. doi: 10.1016/j.athoracsur.2005.03.027.
Stentless aortic bioprostheses offer excellent hemodynamics and potentially improved durability compared with other bioprostheses. The present report describes the clinical and hemodynamic outcomes for the Freestyle aortic root bioprosthesis in a large, multicenter cohort prospectively followed up for 10 years.
A total of 725 patients at 8 centers in North America (668 [92%] aged more than 60 years) were followed up prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis. Implant technique was subcoronary in 509, total root in 178, and root inclusion in 38. Follow-up was 4,488 patient-years (mean 6.2 years/patient).
For subcoronary, full root, and root inclusion groups, 10-year actuarial freedom from structural valve deterioration was 97.0% +/- 2.2%, 96.0% +/- 4.5%, and 90.9% +/- 11.2%, respectively; and actuarial freedom from reoperation was 91.7% +/- 3.5%, 92.3% +/- 6.0%, and 92.0% +/- 10.7%, respectively. Mean pressure gradient at 10 years was 8.9 +/- 7.9 mm Hg for subcoronary, 7.0 +/- 4.1 mm Hg for full root, and 10.0 +/- 11.1 mm Hg for root inclusion groups; effective orifice area was 1.6 +/- 0.5 cm2, 1.6 +/- 0.6 cm2, and 1.7 +/- 0.5 cm2, respectively. Fredom from moderate or more aortic regurgitation at 10 years was good for all three implant groups, but slightly higher for full root (97.7% +/- 1.6%) compared with subcoronary (87.2% +/- 2.8%) patients (p < 0.005).
The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent through 10 years.
与其他生物假体相比,无支架主动脉生物假体具有出色的血流动力学性能,且潜在耐用性更佳。本报告描述了Freestyle主动脉根部生物假体在一个大型多中心队列中10年的前瞻性随访临床和血流动力学结果。
北美8个中心的725例患者(668例[92%]年龄超过60岁)在接受Freestyle无支架生物假体主动脉瓣置换术后进行前瞻性随访。植入技术为冠状动脉下植入509例,全根部植入178例,根部包埋植入38例。随访时间为4488患者年(平均每位患者6.2年)。
对于冠状动脉下植入、全根部植入和根部包埋植入组,10年结构瓣膜退变的精算无事件生存率分别为97.0%±2.2%、96.0%±4.5%和90.9%±11.2%;再次手术的精算无事件生存率分别为91.7%±3.5%、92.3%±6.0%和92.0%±10.7%。10年时冠状动脉下植入组的平均压力阶差为8.9±7.9 mmHg,全根部植入组为7.0±4.1 mmHg,根部包埋植入组为10.0±11.1 mmHg;有效瓣口面积分别为1.6±0.5 cm²、1.6±0.6 cm²和1.7±0.5 cm²。10年时所有三个植入组中重度或以上主动脉瓣反流的无事件生存率均良好,但全根部植入组(97.7%±1.6%)略高于冠状动脉下植入组(87.2%±2.8%)患者(p<0.005)。
Freestyle无支架主动脉根部生物假体是主动脉瓣置换的一种通用选择。临床结果和假体耐用性指标在10年期间仍保持出色。