腿部动脉狭窄的双侧光电容积描记术研究。

Bilateral photoplethysmography studies of the leg arterial stenosis.

作者信息

Erts Renars, Spigulis Janis, Kukulis Indulis, Ozols Maris

机构信息

Institute of Atomic Physics and Spectroscopy, University of Latvia, Riga.

出版信息

Physiol Meas. 2005 Oct;26(5):865-74. doi: 10.1088/0967-3334/26/5/022. Epub 2005 Aug 8.

Abstract

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG signals arrived without delays or with smaller time-shifts not exceeding 14 ms. The reference bilateral PPG signals detected at the fingertips did not show any notable PWTT delays in both groups. Parallel measurements of local blood pressures by means of the oscillometry method with subsequent calculation of the ankle-brachial index were performed. Convincing correlation between the bilateral differences in the local blood pressure (a routine tool for diagnostics of leg stenosis) and in the corresponding PWTT delay (Pearson's coefficient r = 0.93), as well as between the PWTT delay and the ankle-brachial index (r = -0.96) has been established. From the point of view of PWTT delay, the average value of leg stenosis diagnostic threshold was established to be in the range of 23 +/- 9 ms, with full reliability above 32 ms. The obtained data may find further applications in alternative methodologies for detection and/or assessment of arterial occlusions in human extremities.

摘要

一种新开发的便携式多通道光电容积脉搏波描记术(PPG)设备已用于对20名健康对照受试者和45名确诊腿部动脉狭窄患者进行对比研究。在四个身体部位同时检测外周血搏动,即双臂和双腿相同的手指和脚趾。与健康腿部相比,在狭窄腿部外周记录的PPG脉搏要弱得多,由于血管阻力增加导致脉搏波传导时间(PWTT)延长,脉搏到达延迟。闭塞腿部的特定PWTT延迟在20 - 80毫秒范围内,而在健康受试者中,腿部PPG信号无延迟到达或时间偏移较小,不超过14毫秒。在两组中,在指尖检测到的参考双侧PPG信号均未显示出任何明显的PWTT延迟。通过示波法并行测量局部血压,随后计算踝臂指数。已确定局部血压(诊断腿部狭窄的常规工具)的双侧差异与相应的PWTT延迟之间存在令人信服的相关性(皮尔逊系数r = 0.93),以及PWTT延迟与踝臂指数之间的相关性(r = -0.96)。从PWTT延迟的角度来看,腿部狭窄诊断阈值的平均值确定在23±9毫秒范围内,在32毫秒以上具有完全可靠性。所获得的数据可能在检测和/或评估人体四肢动脉闭塞的替代方法中找到进一步的应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验