Suppr超能文献

使用压力传感线检测同侧椎动脉和锁骨下动脉狭窄的连续压力梯度。

Use of a pressure-sensing wire to detect sequential pressure gradients for ipsilateral vertebral and subclavian artery stenoses.

作者信息

Liu Chung-Pin, Ling Yen-Hung, Kao Hsien-Li

机构信息

Department of Internal Medicine, Division of Cardiology, National Taiwan University Hospital.

出版信息

AJNR Am J Neuroradiol. 2005 Aug;26(7):1810-2.

Abstract

Endoluminal stent placement is safe and effective in the treatment of symptomatic ostial stenoses of the vertebral artery (VA) and proximal subclavian artery (SCA). However, determining the relative importance of an individual lesion on angiography is difficult when VA and SCA stenoses are concurrent. Pressure-sensing wires help in determining the functional significance of coronary artery stenosis. We present a case of ipsilateral VA and SCA stenoses in which a pressure-sensing wire was used in making interventional decisions.

摘要

腔内支架置入术治疗椎动脉(VA)和锁骨下动脉近端(SCA)有症状的开口处狭窄是安全有效的。然而,当VA和SCA狭窄同时存在时,很难在血管造影上确定单个病变的相对重要性。压力传感导丝有助于确定冠状动脉狭窄的功能意义。我们报告一例同侧VA和SCA狭窄病例,其中使用压力传感导丝来做出介入决策。

相似文献

2
3
4
Subclavian steal syndrome treated by kissing stenting of the subclavian and vertebral arteries.
BMJ Case Rep. 2020 May 18;13(5):e233153. doi: 10.1136/bcr-2019-233153.
5
The effect of stenting on blood pressure in hypertensive patients with symptomatic proximal subclavian or vertebral artery stenosis.
Catheter Cardiovasc Interv. 2020 Feb;95 Suppl 1:633-640. doi: 10.1002/ccd.28650. Epub 2019 Dec 23.
6
Colour Doppler imaging of partial subclavian steal syndrome.
Neuroradiology. 1993;35(4):293-5. doi: 10.1007/BF00602619.
7
Subclavian steal despite ipsilateral vertebral occlusion.
J Vasc Surg. 1985 Nov;2(6):913-6. doi: 10.1067/mva.1985.avs0020913.
8
Hyperperfusion syndrome after stent placement for subclavian artery stenosis: case report.
Neurol Med Chir (Tokyo). 2012;52(12):902-5. doi: 10.2176/nmc.52.902.

引用本文的文献

本文引用的文献

2
How to prevent unnecessary coronary interventions: identifying lesions responsible for ischemia in the cath lab.
Curr Opin Cardiol. 2003 Sep;18(5):394-9. doi: 10.1097/00001573-200309000-00012.
3
Coronary pressure measurement after stenting predicts adverse events at follow-up: a multicenter registry.
Circulation. 2002 Jun 25;105(25):2950-4. doi: 10.1161/01.cir.0000020547.92091.76.
4
Coronary thermodilution to assess flow reserve: validation in humans.
Circulation. 2002 May 28;105(21):2482-6. doi: 10.1161/01.cir.0000017199.09457.3d.
9
Practice and potential pitfalls of coronary pressure measurement.
Catheter Cardiovasc Interv. 2000 Jan;49(1):1-16. doi: 10.1002/(sici)1522-726x(200001)49:1<1::aid-ccd1>3.0.co;2-5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验