三种用于从尿液标本中提取核酸的商业系统的比较评估。

Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.

作者信息

Tang Yi-Wei, Sefers Susan E, Li Haijing, Kohn Debra J, Procop Gary W

机构信息

Department of Medicine, Vanderbilt University School of Medicine, Nashville, Tennessee 37232-5310, USA.

出版信息

J Clin Microbiol. 2005 Sep;43(9):4830-3. doi: 10.1128/JCM.43.9.4830-4833.2005.

Abstract

A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.

摘要

对于紧急检测而言,需要一种能够处理少量样本、检测周转时间短且实际操作时间短的核酸提取系统。我们对三种系统进行了比较验证:MagNA Pure compact系统(Compact)、NucliSens miniMAG提取仪(miniMAG)和BioRobot EZ1系统(EZ1)。总共使用了75份提交用于多瘤病毒BK病毒检测的尿液样本。分别通过miniMAG、EZ1和Compact制备的核酸提取物中,检测到人类β-肌动蛋白基因的样本数分别为75份(100%)、75份(100%)和72份(96%)。在这三种系统中,miniMAG产生的核酸量最高且精度最佳。三种提取系统制备的核酸提取物中BKV检测的符合率为100%。当运行一整套样本时,miniMAG的实际操作时间和检测周转时间分别为105.7分钟和121.1分钟,EZ1为6.1分钟和22.6分钟,Compact为7.4分钟和33.7分钟。EZ1和Compact系统能够正确处理自动核酸提取,很好地满足了对零星但紧急样本检测的需求。miniMAG产生的核酸量最高,表明该系统对于含有少量目标微生物的样本最为适用。

相似文献

引用本文的文献

8
Comparison of an automated nucleic acid extraction system with the column-based procedure.自动核酸提取系统与基于柱的方法的比较。
Eur J Microbiol Immunol (Bp). 2015 Mar;5(1):94-102. doi: 10.1556/EUJMI-D-14-00040. Epub 2015 Mar 26.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验