Digital mobile telephones and interference of ophthalmic equipment.

作者信息

Ang G S, Lian P, Ng W S, Whyte I, Ong J M

机构信息

Department of Ophthalmology, Raigmore Hospital, Inverness, and Norfolk and Norwich University Hospital, UK.

出版信息

Eye (Lond). 2007 Jan;21(1):29-32. doi: 10.1038/sj.eye.6702110. Epub 2005 Sep 30.

DOI:10.1038/sj.eye.6702110
PMID:16200056
Abstract

AIM

To assess the effect of mobile telephone electromagnetic interference on electronic ophthalmic equipment.

METHODS

Prospective audit with mobile telephones placed at distances of 3 m, 1 m, and 30 cm from, and in contact with, electronic ophthalmic equipment. Any interruption or cessation of the function of the ophthalmic device was assessed with the mobile telephones in standby, and in dialling or receiving modes. Any alterations of displayed digital figures or numbers were also assessed.

RESULTS

A total of 23 electronic ophthalmic devices in two hospital ophthalmology outpatient departments were evaluated. All six mobile telephones used, and 22 (95.7%) of the 23 ophthalmic equipment evaluated had the Conformité Européene (CE) mark. No device showed any interruption or cessation of function. There were no alterations of displayed digital figures or numbers. The only effect of any kind was found with four instruments (1 non-CE marked), where there was temporary flickering on the screen, and only occurred when the mobile telephones were dialling or receiving at a distance of 30 cm or less from the instruments.

CONCLUSION

This study shows that among the electronic ophthalmic devices tested, none suffered failure or interruption of function, from mobile telephone interference. Although not comprehensive for all ophthalmic equipment, the results question the need for a complete ban of mobile telephones in ophthalmic departments. It highlights the need for a controlled, objectively measured study of the clinically relevant effects of mobile telephones in the ophthalmology outpatient setting.

摘要

相似文献

1
Digital mobile telephones and interference of ophthalmic equipment.
Eye (Lond). 2007 Jan;21(1):29-32. doi: 10.1038/sj.eye.6702110. Epub 2005 Sep 30.
2
[Cellular phone interference with medical instruments].[手机对医疗器械的干扰]
Harefuah. 1997 Mar 2;132(5):313-8, 382.
3
Interference by new-generation mobile phones on critical care medical equipment.新一代移动电话对重症监护医疗设备的干扰。
Crit Care. 2007;11(5):R98. doi: 10.1186/cc6115.
4
Cellular telephone interference with medical equipment.移动电话对医疗设备的干扰。
Mayo Clin Proc. 2005 Oct;80(10):1286-90. doi: 10.4065/80.10.1286.
5
Interference with cardiac pacemakers by cellular telephones.移动电话对心脏起搏器的干扰。
N Engl J Med. 1997 May 22;336(21):1473-9. doi: 10.1056/NEJM199705223362101.
6
Mobile communication devices causing interference in invasive and noninvasive ventilators.移动通讯设备对有创和无创呼吸机造成干扰。
J Crit Care. 2007 Jun;22(2):137-41. doi: 10.1016/j.jcrc.2006.09.006. Epub 2007 Jan 31.
7
[Do mobile telephones have adverse effects on the functions of implantable cardioverter defibrillators?].移动电话对植入式心脏复律除颤器的功能有不良影响吗?
Anadolu Kardiyol Derg. 2002 Mar;2(1):45-8, AXVII.
8
Interference of electrocardiographic recordings by a mobile telephone.
Cardiol Young. 2007 Jun;17(3):328-9. doi: 10.1017/S1047951107000443. Epub 2007 Apr 20.
9
Clinical testing of cellular phone ringing interference with automated external defibrillators.手机铃声对自动体外除颤器干扰的临床测试。
Resuscitation. 2006 Dec;71(3):391-4. doi: 10.1016/j.resuscitation.2006.04.013. Epub 2006 Sep 20.
10
In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators.植入式心脏复律除颤器患者体内数字蜂窝电话测试
Eur Heart J. 2001 Aug;22(15):1337-42. doi: 10.1053/euhj.2000.2516.